In response to the recent rise in cyber threat due to the Russian-Ukraine crisis, NetApp is actively monitoring the global security intelligence and updating our cybersecurity measures. We follow U.S. Federal Government guidance and remain on high alert. Customers are encouraged to monitor the Cybersecurity and Infrastructure Security (CISA) website for new information as it develops and remain on high alert.

ONTAP 驱动器出现故障,并显示 " 故障 - 不支持 " 状态—解决指南

Views:
17
Visibility:
Public
Votes:
0
Category:
disk-drives
Specialty:
hw
Last Updated:

适用场景

  • ONTAP 9
  • AFF 系统
  • FAS 系统
  • 驱动器

问题描述

按照本指南帮助您找到正确的解决方案 您的问题或问题描述

Cluster::> system node run -node <node name> -command sysconfig -a

07.0 : 0.0GB 0B/sect (Failed-Unsupported)
07.1 : 0.0GB 0B/sect (Failed-Unsupported)
07.2 : 0.0GB 0B/sect (Failed-Unsupported)
  • 可以在系统上观察到以下 EMS 消息:

::>Event log show

Sun Nov 22 12:07:42 +0100 [node-01: scsi_cmdblk_strthr_admin: scsi.cmd.pastTimeToLive:error]: Disk device 0a.07.0: request failed after try #1: cdb 0x12. 
Sun Nov 22 12:07:42 +0100 [node-01: scsi_cmdblk_strthr_admin: disk.init.err.unsupported:error]: Disk 0b.07.0 is not recognized as a supported disk and cannot be used on this node.

 