In response to the recent rise in cyber threat due to the Russian-Ukraine crisis, NetApp is actively monitoring the global security intelligence and updating our cybersecurity measures. We follow U.S. Federal Government guidance and remain on high alert. Customers are encouraged to monitor the Cybersecurity and Infrastructure Security (CISA) website for new information as it develops and remain on high alert.

在 BMC 上禁用 IPv4 后, ONTAP 9 系统无法使用 " 此版本不支持此平台 " 启动

Views:
19
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
hw
Last Updated:

适用于

在以下系统之一上运行的 ONTAP 9.3 或更早版本:

  • AFF A220
  • FAS2720
  • FAS2750

问题

  • IPv4 已禁用,并且 BMC 只有 IPv6 处于活动状态。
  • 执行存储器或 BMC 重新启动。
  • 启动过程将显示以下消息和失败:

IPMI:Read midplane FRU common header:failed
***************************************************
 This platform is not supported in this release.
 The system will now halt

 