在 ONTAP 升级期间,节点停留在 "BIOS image updated , resetting to load defaults" 处

Views:
13
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
hw
Last Updated:

适用于

  • FAS8200
  • 自动无中断升级( ANDU ),从 9.5P9 升级到 9.7P7

问题

  • 节点在更新期间会出现消息,并显示消息,但确实会出现此问题 请勿继续
 
BIOS image updated, resetting to load defaults
 
  • ONTAP 更新状态为已暂停
 
SP 事件日志显示节点发生 L2 watchdog 重置
 
[SysFW.notice]: Updating flash. Current BIOS version: 11.1
[SysFW.notice]: New BIOS version: 11.4
[IPMI.notice]: 3f01 | 02 | EVT: 0301ffff | CPU0_Error | Assertion Event, "State Asserted"
[IPMI Event.critical]: L2 watchdog timeout power cycle
[IPMI.notice]: 4001 | 02 | EVT: 6fc302ff | System_Watchdog | Assertion Event, "Power cycle"
[IPMI Event.critical]: L2 watchdog action completed
[SP.notice]: Delaying L2_WDOG ASUP email for 120 seconds
[IPMI.notice]: 4101 | 02 | EVT: 6fc100ff | System_FW_Status | Assertion Event, "Unspecified"
 

 