适用场景

  • FAS
  • AFF

问题描述

  • 节点发生故障并出现以下事件:

Wed May 25 00:48:24 UTC [pv35p45im-filerm45003: env_mgr: monitor.temp.unreadable:info]: The controller temperature (CPU1 Temp Margin) is not readable.
Wed May 25 00:48:24 UTC [pv35p45im-filerm45003: env_mgr: monitor.power.unreadable:info]: A power sensor PVCCP CPU0 in the controller module is not readable.
Wed May 25 00:51:16 UTC [pv35p45im-filerm45003: spsm_listener: sp.heartbeat.stopped:warning]: Have not received a IPMI heartbeat from the Service Processor (SP) in last 20 seconds.
Wed May 25 00:51:19 UTC [pv35p45im-filerm45003: env_mgr: callhome.c.fan.fru.fault:error]: Call home for CHASSIS FAN FRU FAILED: SysFan3 F1
Wed May 25 00:51:19 UTC [pv35p45im-filerm45003: env_mgr: monitor.chassisFan.stop:alert]: Chassis fan contains at least one stopped fan: SysFan3 F1 (failed)
Wed May 25 00:51:19 UTC [pv35p45im-filerm45003: env_mgr: monitor.temp.unreadable:info]: The controller temperature (In Flow Temp) is not readable.
Wed May 25 00:51:19 UTC [pv35p45im-filerm45003: env_mgr: monitor.chassisTemperature.state.unknown:warning]: Chassis temperature state is unknown: Multiple Temp sensors are unreadable. System will be shutdown in 2 minutes.
Wed May 25 00:51:19 UTC [pv35p45im-filerm45003: env_mgr: monitor.power.unreadable:info]: A power sensor PCH Hot in the controller module is not readable.
Wed May 25 00:51:19 UTC [pv35p45im-filerm45003: env_mgr: monitor.power.unreadable:info]: A power sensor P5V STBY in the controller module is not readable.
Wed May 25 00:51:19 UTC [pv35p45im-filerm45003: env_mgr: monitor.power.unreadable:info]: A power sensor P3.3V STBY in the controller module is not readable.
Wed May 25 00:51:19 UTC [pv35p45im-filerm45003: env_mgr: monitor.power.unreadable:info]: A power sensor P1.8V STBY in the controller module is not readable.
Wed May 25 00:51:19 UTC [pv35p45im-filerm45003: env_mgr: monitor.power.unreadable:info]: A power sensor P0.9V STBY in the controller module is not readable.
Wed May 25 00:51:19 UTC [pv35p45im-filerm45003: env_mgr: monitor.power.unreadable:info]: A power sensor PVDDQ DDR3 AB in the controller module is not readable.
Wed May 25 00:51:19 UTC [pv35p45im-filerm45003: env_mgr: monitor.power.unreadable:info]: A power sensor PVTT DDR3 AB in the controller module is not readable.
Wed May 25 00:51:19 UTC [pv35p45im-filerm45003: env_mgr: monitor.shutdown.emergency:EMERGENCY]: Emergency shutdown: Multiple chassis fans have failed.
Wed May 25 00:51:19 UTC [pv35p45im-filerm45003: env_mgr: callhome.fans.failed:EMERGENCY]: Call home for MULTIPLE FAN FAILURE
Wed May 25 00:51:19 UTC [pv35p45im-filerm45003: statd: monitor.shutdown.emergency:EMERGENCY]: Emergency shutdown: Environmental Reason Shutdown (Temperature critical)

  • 节点重新启动并开始等待交还状态。
  • 重新启动期间的服务处理器状态显示未知。
    Node>sysconfig -a

Service Processor
                    Status: Unknown
                    IPMI: unknown
                  PKT: unknown

  • 可能会从SP日志中看到SP重置事件。

sp>events all
SP recovered successfully after a reset from primary FW image.

  •  注意到服务处理器在节点重新启动期间自动重新启动。

sp>sp uptime
02:17:43 up 2:27, load average: 1.29, 1.15, 1.10

Scan to view the article on your device
CUSTOMER EXCLUSIVE CONTENT

Registered NetApp customers get unlimited access to our dynamic Knowledge Base.

New authoritative content is published and updated each day by our team of experts.

Current Customer or Partner?

Sign In for unlimited access

New to NetApp?

Learn more about our award-winning Support