节点关闭、配对节点触发PSU严重错误

Views:
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
hw<a>2009年142032年</a>
Last Updated:

适用场景

  • FAS8200
  • ONTAP 9
  • SP固件5.10

问题描述

  • 无法访问节点崩溃和SP。
  • 配对节点会触发以下PSU错误。

HA Group Notification (Health Monitor process cphm: CriticalFruMultiFaultAlert[PSQ0A2184600020]) ALERT
HA Group Notification (CHASSIS POWER SUPPLY DEGRADED: PS 1) ERROR
HA Group Notification (CHASSIS POWER DEGRADED: Power Supply Status Critical: PSU1, PSU2.) ERROR

  • 在配对节点上、PSU1和PSU2将显示BAD 状态from sp-latest-ipmi

sp-latest-ipmi:
/usr/local/bin/environ -show_all
================================
Sensor Name State Current Critical Warning Warning Critical
          Reading Low    Low   High   High
-------------------------------------------------------------------------------------------------
PSU2 Bad      TRUE
PSU1 Bad      TRUE
PSU2 need     replacement NO
PSU1need replacement NO
PSU2       BAD
PSU1       BAD

 