跳转到主内容

节点PSU FRU报告在ONTAP 升级后无法访问

Views:
4
Visibility:
Public
Votes:
0
Category:
fas-systems<a>FAS2554</a><a>PSU</a><a>2008558812</a>
Specialty:
hw
Last Updated:

适用场景

  • FAS2554

问题描述

  • 在将ONTAP 从9.7P7升级到9.7P8后、节点报告PSU FRU不可访问、但运行正常。
  • "sysconfig -m"和"环境"输出缺少PSU详细信息。
  • 示例:
::*> system chassis fru show Chassis ID FRU Type State Nodes Sharing the FRU ------------------- ---------- -------- ----------- ----------------------- 021929008473 Fan1 fan GOOD stor-sn02-09, stor-sn02-10 021929008473 Fan2 fan GOOD stor-sn02-09, stor-sn02-10 021929008473 Fan3 fan GOOD stor-sn02-09, stor-sn02-10 031819002171 stor-sn02-07 controller ok stor-sn02-07 031819002171 stor-sn02-08 controller ok stor-sn02-08 BPJWX7912213789 stor-sn02-04 controller ok stor-sn02-04 BPJWX7912213789 stor-sn02-03 controller ok stor-sn02-03 021929008473 stor-sn02-10 controller ok stor-sn02-10 021929008473 stor-sn02-09 controller ok stor-sn02-09 031747000981 stor-sn02-05 controller ok stor-sn02-05 031747000981 stor-sn02-06 controller ok stor-sn02-06 BPJWX7912213789 PSU4 FRU psu GOOD stor-sn02-04 BPJWX7912213789 PSU3 FRU psu GOOD stor-sn02-04 BPJWX7912213789 PSU1 FRU psu GOOD stor-sn02-04 BPJWX7912213789 PSU2 FRU psu GOOD stor-sn02-04 031747000981 PSU2 FRU psu GOOD stor-sn02-06, stor-sn02-05 031747000981 PSU1 FRU psu GOOD stor-sn02-06, stor-sn02-05 031819002171 PSU2 FRU psu GOOD stor-sn02-08, stor-sn02-07 031819002171 PSU1 FRU psu GOOD stor-sn02-08, stor-sn02-07 021929008473 PSU1 psu GOOD stor-sn02-09, stor-sn02-10 021929008473 PSU2 psu GOOD stor-sn02-09, stor-sn02-10 BPJWX7912213789 PSU1 FRU psu NOT_PRESENT stor-sn02-03 BPJWX7912213789 PSU2 FRU psu NOT_PRESENT stor-sn02-03 BPJWX7912213789 PSU3 FRU psu NOT_PRESENT stor-sn02-03 BPJWX7912213789 PSU4 FRU psu NOT_PRESENT stor-sn02-03 25 entries were displayed.

 

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.