跳转到主内容

在 AF-A800 , AF-A320 , AF-A400 , FAS8300 和 FAS8700 上运行 NVDIMMADHealthAlert

Views:
3
Visibility:
Public
Votes:
0
Category:
aff-series<a>2008866234</a>
Specialty:
hw
Last Updated:

适用场景

  • ONTAP 9
  • AFF A800、AFF A400、AFF A320
  • FAS8700、FAS8300
  • NVDIMM

问题描述

EMS

Sun Jun 06 17:17:15 -0700 [NetApp1: nphmd: hm.alert.raised:alert]: Alert Id = NVDIMMBadHealthAlert , Alerting Resource = /dev/nvdimm0:NetApp1 raised by monitor controller

 

AutoSupport 部分: NVDIMM-status 

示例: 

 Total NVDIMM on this platform is 1 -------------------------------------------------- DIMM(/dev/nvdimm0) Page:0 -------------------------------------------------- 0x0000: 00 0a 0a 01 01 00 21 3c 25 3c 25 34 34 00 00 00 0x0010: 1f 2e 00 00 03 15 03 0b 68 81 02 00 68 81 1e 80 0x0020: 05 80 78 80 05 00 00 40 1f ac 0d d0 07 a0 0f 90 0x0030: 33 08 08 dc 05 10 80 00 00 00 70 03 00 00 00 00 0x0040: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 0x0050: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 0x0060: a5 00 00 00 00 00 00 00 01 00 04 00 00 00 00 00 0x0070: 08 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 0x0080: 04 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 0x0090: 01 00 00 00 00 00 00 00 0a 00 00 00 00 00 00 00 0x00a0: 01 40 00 00 00 00 00 00 00 00 01 00 00 00 00 00 0x00b0: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 0x00c0: 56 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 0x00d0: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 0x00e0: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 0x00f0: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 ----------------------------------------------------- -------------------------------------------------- DIMM(/dev/nvdimm0): -------------------------------------------------- Controller Ready: Yes Controller Busy: No Energy Policy managed by: HOST Save_N Low During CSAVE: Yes Save_N Enabled(ARMED): Yes Data on the Flash: NotValid Module is Health: No Module Status(0x0040): NVDIMM FIRMWARE error <------------- Flash Lifetime: 86% Flash Lifetime Status: Normal 

运行状况警报示例:

::>system health alert show

节点 NetApp 1
监控 controller
Alert ID NVDIMMADHealthAlert
警报资源 /dev/nvdimm0:NetApp1
子系统 主板
指示时间 Sun Jun 06 17:17:15 2021
感知的严重性 重大
可能的发生原因 硬件降性
问题描述 节点"NetApp1"上的NVDIMM"NVDIMM-N 0 (DIMM-11)"指示状态为已降级。
更正操作 请联系技术支持以获得有关更换NVDIMM模块的帮助。
可能的影响 NVDIMM降级后可能会丢失数据。
确认 false
禁止 false
策略 NVDIMMADHealthPolicy
确认者  
禁止程序  
追加信息

节点:NetApp1
唯一名称:/dev/nvdimm0:NetApp1
设备名称和DIMM插槽:/dev/nvdimm0
运行状况:降级
运行状况说明: NVDIMM固件错误
生命周期状态: 正常
生命周期状态说明:无

 