问题

  • 客户在 E 系列存储阵列上执行固件更新时,连接的 ONTAP Fabric MetroCluster 报告多个磁盘因 SCSI 超时错误而出现故障:
 
示例:
Fri Dec 04 20:09:18 EST [node1: config_thread: raid.config.filesystem.disk.not.responding:notice]: File system Disk /node1/plex0/rg0/switch1:12.126L119 Shelf - Bay - [NETAPP   INF-01-00        0842] S/N [xxxxxxxxxxxxxxxxxxxxxx] UID [xxxxxxxx:xxxxxxxx:xxxxxxxx:xxxxxxxx:00000000:00000000:00000000:00000000:00000000:00000000] is not responding.
  • 这些错误会导致 MetroCluster 中的两个集群出现多个 SyncMirror 丛故障。

示例:

Aggregate aggrname (online, raid0, mirror degraded) (block checksums)
  Plex /aggrname/plex0 (offline, failed, inactive)
    RAID group /aggrname/plex0/rg0 (partial, block checksums)

      RAID Disk   Device                HA  SHELF BAY CHAN Pool Type  RPM  Used (MB/blks)    Phys (MB/blks)
      ---------   ------                ------------- ---- ---- ---- ----- --------------    --------------
      data   FAILED                   N/A                        13972000/ -
      data      switch1:12.126L78    0f    -   -          0   LUN   N/A 13972000/28614656000 14000000/28672000000
      data   FAILED                   N/A                        13972000/ -
      data      switch1:12.126L82    0f    -   -          0   LUN   N/A 13972000/28614656000 14000000/28672000000
      data      switch1:12.126L80    0f    -   -          0   LUN   N/A 13972000/28614656000 14000000/28672000000
      data   FAILED                   N/A                        13972000/ -
      Raid group is missing 3 disks.

 