跳转到主内容

AFF A250/FAS500f Low BAT_dstg_Cycls发生原因 电池(容量低)错误

Views:
40
Visibility:
Public
Votes:
0
Category:
aff-series<a>NVRAM 电池</a><a>2008665158</a><a>1356325</a>
Specialty:
hw
Last Updated:

适用场景

  • AFF A250
  • FAS500f
  • NVRAM 电池固件 C0 或更低版本

BMC node_name> system battery show
DeviceChemistry      :  LION
ChemistryID        :  0x1968
DeviceName         :  bq40z50-R2
ID             :  27100073
ManufacturerName      :  Inv27100073+C0
FW version         : C0

问题描述

  • 事件 BATTERY (capacity low)

1/1/2022 00:00:00  node-name  ALERT      callhome.battery.low: Call home for BATTERY_LOW.
1/1/2022 00:00:00  node-name  EMERGENCY    monitor.nvramLowBattery: NVRAM battery is dangerously low.
1/1/2022 00:00:00  node-name  ALERT      callhome.battery.warning: Call home for BATTERY (capacity low) WARNING.

  • 报告错误和更正(正常)的 EMS 消息

[node_name: env_mgr: nvmem.battery.capLowWarn:error]: The NVMEM battery capacity is below normal (5 cycles).
[node_name: env_mgr: callhome.battery.notice:notice]: Call home for BATTERY (capacity low) NOTICE.
[node_name: env_mgr: nvmem.battery.capNormal:notice]: The NVMEM battery capacity is normal.

  • 电池电量低的 BMC 事件

123 | 06/16/2022 | 16:56:09 | Battery #0x49 | Lower Non-critical going low

  • system sensors show 报告 Bat_Dstg_Cycles 小于或等于 lnc

=================== sensor ==========================
Sensor name      | reading    | unit    | status| lnr       | lcr       | lnc       | unc       | ucr       | unr
Bat_Temp         | 34.500     | degrees C  | ok    | 0.000     | 0.000     | 5.000     | 60.000    | 75.000    | 127.500
Bat_Volt         | 8.100      | Volts      | ok    | 0.000     | 5.500     | 5.600     | 8.500     | 8.600     | 12.750
Bat_Curr         | 0.000      | Amps       | ok    | na        | na        | na        | 1.200     | 1.520     | 2.540
Bat_Rem_Cap      | 9.840      | Watts * hour | ok  | na        | na        | na        | na        | na        | na
Bat_Full_Cap     | 10.800     | Watts * hour | ok  | na        | na        | na        | na        | na        | na
Bat_Charge_Curr  | 0.000      | Amps       | ok    | na        | na        | na        | 2.200     | 2.300     | 5.100
Bat_Charge_Volt  | 8.200      | Volts      | ok    | na        | na        | na        | 8.900     | 9.000     | 12.750
Bat_Design_Cap   | 18.400     | Watts * hour | ok  | na        | na        | na        | na        | na        | na
Bat_Initial_Fcc  | 20.400     | Watts * hour | ok  | na        | na        | na        | na        | na        | na
Bat_Dstg_Cycles  | 4.000      | cycles     | nc    | na        | 2.000     | 5.000     | na        | na        | na
Bat_Cycle_Cnt    | 0.000      | cycles     | ok    | na        | na        | na        | na        | na        | na
Bat_Power_Fault  | 0x0        | discrete   | 0x0180| na        | na        | na        | na        | na        | na
Bat_Dsg_FET_Flt  | 0x0        | discrete   | 0x0280| na        | na        | na        | na        | na        | na
Bat_Chg_FET_Flt  | 0x0        | discrete   | 0x0280| na        | na        | na        | na        | na        | na
Bat_Pack_Invalid | 0x0        | discrete   | 0x0180| na        | na        | na        | na        | na        | na
Bat_Lrn_Active   | 0x0        | discrete   | 0x0180| na        | na        | na        | na        | na        | na

 