跳转到主内容

集群端口上发生大量 CRC 错误

Views:
15
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
hw
Last Updated:

适用于

  • FAS 2750
  • ONTAP 9

问题

  • 使用的 e0b 端口上的 CRC 错误计数为 1212 次 ifconfig:

-- interface  e0b  (232 days, 2 hours, 21 minutes, 3 seconds) --

RECEIVE
 Total frames:    252m | Frames/second:    13  | Total bytes:    39644m
 Bytes/second:    1977  | Total errors:    1218  | Errors/minute:     0 
 Total discards:    0  | Discards/minute:    0  | Multi/broadcast:  1020k
 Non-primary u/c:    0  | CRC errors:     1212  | Runt frames:      0 
 Fragment:       0  | Long frames:      0  | Jabber:        3 
 Length errors:     3  | No buffer:       0  | Xon:          0 
 Xoff:         0  | Pause:         0  | Jumbo:       1293k
 Noproto:        0  | Error symbol:    236  | Illegal symbol:   199 
 Bus overruns:     0  | Queue drops:      0  | LRO segments:    249m
 LRO bytes:     26713m
| LRO6 segments:     0  | LRO6 bytes:      0 
 Bad UDP cksum:     0  | Bad UDP6 cksum:    0  | Bad TCP cksum:     0 
 Bad TCP6 cksum:    0  | Mcast v6 solicit:   0 
TRANSMIT
 Total frames:    561m | Frames/second:    28  | Total bytes: 139g
 Bytes/second:    6980  | Total errors:     0  | Errors/minute:     0 
 Total discards:    0  | Queue overflow:    0  | Multi/broadcast:  1031k
 Xon:          0  | Xoff:         0  | Pause:         0 
 Jumbo:       2565k | Cfg Up to Downs:    2  | TSO non-TCP drop:   0 
 Split hdr drop:    0  | Timeout:        0  | TSO segments:    402k
 TSO bytes:     4840m | TSO6 segments:     0  | TSO6 bytes:      0 
 HW UDP cksums:    154k | HW UDP6 cksums:    0  | HW TCP cksums:    556m
 HW TCP6 cksums:    0  | Mcast v6 solicit:   0 
DEVICE
 Mcast addresses:    3  | Rx MBuf Sz:     4096 
LINK INFO
 Speed:       10000M | Duplex:       full | Flowcontrol:     none
 Media state:    activ
e | Up to downs: 8

  • EMS 错误消息每小时持续提供以下输出:

Tue Dec 01 04:04:26 JST [node 2: intr: netif.linkErrors:error]: Excessive link errors on network interface e0b. Might indicate a bad cable, switch port, or NIC, or that a cable connector is not fully inserted in a socket. On a 10/100 port, might indicate a duplex mismatch.
Tue Dec 01 05:04:27 JST [node 2: intr: netif.linkErrors:error]: Excessive link errors on network interface e0b. Might indicate a bad cable, switch port, or NIC, or that a cable connector is not fully inserted in a socket. On a 10/100 port, might indicate a duplex mismatch.
Tue Dec 01 06:04:27 JST [node 2: intr: netif.linkErrors:error]: Excessive link errors on network interface e0b. Might indicate a bad cable, switch port, or NIC, or that a cable connector is not fully inserted in a socket. On a 10/100 port, might indicate a duplex mismatch.
Tue Dec 01 07:04:27 JST [node 2: intr: netif.linkErrors:error]: Excessive link errors on network interface e0b. Might indicate a bad cable, switch port, or NIC, or that a cable connector is not fully inserted in a socket. On a 10/100 port, might indicate a duplex mismatch.
Tue Dec 01 08:04:28 JST [node 2: intr: netif.linkErrors:error]: Excessive link errors on network interface e0b. Might indicate a bad cable, switch port, or NIC, or that a cable connector is not fully inserted in a socket. On a 10/100 port, might indicate a duplex mismatch.
Tue Dec 01 09:04:29 JST [node 2: intr: netif.linkErrors:error]: Excessive link errors on network interface e0b. Might indicate a bad cable, switch port, or NIC, or that a cable connector is not fully inserted in a socket. On a 10/100 port, might indicate a duplex mismatch.

  • 即使在作为隔离更换 HA 配对控制器 e0b 端口之间的 SAS 缆线后,上述错误消息也不会停止。

k-tenant-str::> event log show
Time         Node Severity    Event
------------------- ---------------- ------------- ---------------------------
1/5/2021 15:11:21 node 2   ERROR      netif.linkErrors: Excessive link errors on network interface e0b. Might indicate a bad cable, switch port, or NIC, or that a cable connector is not fully inserted in a socket. On a 10/100 port, might indicat
e a duplex mismatch.
1/5/2021 14:54:52   node 1   EMERGENCY    vifmgr.clus.linkdown: The cluster port e0b on node node 1 has gone down unexpectedly.
1/5/2021 14:54:52   node 2   EMERGENCY    vifmgr.clus.linkdown: The cluster port e0b on node node 2 has gone down unexpectedly.
1/5/2021 14:11:20   node 2   ERROR      netif.linkErrors: Excessive link errors on network interface e0b. Might indicate a bad cable, switch port, or NIC, or that a cable connector is not fully inserted in a socket. On a 10/100 port, might indicate a duplex mismatch.
1/5/2021 13:11:20   node 2   ERROR netif.linkErrors: Excessive link errors on network interface e0b. Might indicate a bad cable, switch port, or NIC, or that a cable connector is not fully inserted in a socket. On a 10/100 port, might indicate a duplex mismatch.
1/5/2021 12:11:19   node 2   ERROR      netif.linkErrors: Excessive link errors on network interface e0b. Might indicate a bad cable, switch port,
 or NIC, or that a cable connector is not fully inserted in a socket. On a 10/100 port, might indicate a duplex mismatch.
Press <space> to page down, <return> for next line, or 'q' to quit... q
6 entries were displayed.

  • 更换缆线前后, CRC 错误计数不会增加。 
  • 此设备为无交换机集群配置,目标 e0b 端口是一个端口,可将节点 1 作为集群 LIF 端口直接连接到节点 2 。
  • 连接到速度和双工的每个节点之间的端口没有区别,也不使用 SFP 等收发器。 

 

CUSTOMER EXCLUSIVE CONTENT

Registered NetApp customers get unlimited access to our dynamic Knowledge Base.

New authoritative content is published and updated each day by our team of experts.

Current Customer or Partner?

Sign In for unlimited access

New to NetApp?

Learn more about our award-winning Support