跳转到主内容

IOM 升级需要冷交换

Views:
45
Visibility:
Public
Votes:
0
Category:
disk-shelves
Specialty:
hw
Last Updated:

执行

执行

适用场景

SAS磁盘架和基于SAS的机箱:

  • DS4243
  • DS4246
  • DS2246

问题描述

  • 本文介绍冷插拔升级所需的步骤。
  • 如果要将磁盘架中的IOM模块更换为其他型号、则需要在更换期间关闭以下组件:
    • 连接到受影响磁盘架的所有节点。
    • 连接到受影响磁盘架的所有ATto网桥(如果适用)。
    • 要更改IOM型号的磁盘架。
  • 可能的升级:
    • IOM3到 IOM6
    • IOM3到 IOM12*
    • IOM6到 IOM12*

*请注意IOM3/IOM6 (Qsp)和IOM12 (MiniSAS-HD)之间的SAS端口差异

 

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.