适用场景

  • FAS 存储节点(AFF 节点不受影响)
  • ONTAP 9.8或9.9.1
  • 在同一节点上具有本地层和云层的本地FabricPool 配置
  • 一个节点托管本地层的HA对和托管云层的HA配对节点、在接管时受影响

问题描述

  • 分层策略不会 none 分配给卷、而分层到云层处于活动状态。
  • 节点意外重新启动并显示崩溃消息:
Host memory checksum mismatch on WRITE VERIFY: Disk <disk_ID>, Disk Block #XXXX: Volume <Volume_name>, FileId XXX,File Block #XXX: Expected 0xYYYYYYYY, Recomputed as 0xZZZZZZZZ in SK process disk_server_0 on release 9.X (C)
  • 如果接管会将云层和性能层置于一个节点、则接管可能会导致崩溃。
  • 配对节点发出HA接管后、可能会发生相同的意外重新启动、从而导致HA对中断。
  • 如果HA对中的每个节点仅拥有本地层或云层、则只有在发出接管后才会触发崩溃。
  • 发生崩溃后的RAID擦洗揭示了奇偶校验错误、并引用了云层聚合:

[node-02: raidio_thread: raid_rg_scrub_cksum_err_1:notice]: params: {'disk_rpm': '10000', 'vendor': 'NETAPP  ', 'firmware_revision': 'NA01', 'shelf': '23', 'disk_info': 'Disk /<cloud_tier_aggregate>/plex0/rg1/0c.23.8 Shelf 23 Bay 8 [NETAPP   X343_TA15E1T8A10 NA01] S/N [XXX] UID [5000039B:3840A21C:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000]', 'site': 'Local', 'bay': '8', 'carrier': '', 'serialno': 'XXX', 'owner': '', 'model': 'X343_TA15E1T8A10', 'disk_type': '4', 'blockNum': '17612'}

[node-02: raidio_thread: raid_rg_readerr_repair_cksum_stored_1:notice]: params: {'disk_rpm': '10000', 'vendor': 'NETAPP  ', 'firmware_revision': 'NA01', 'shelf': '23', 'disk_info': 'Disk /<cloud_tier_aggregate>/plex0/rg1/0c.23.8 Shelf 23 Bay 8 [NETAPP   X343_TA15E1T8A10 NA01] S/N [XXX] UID [5000039B:3840A21C:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000]', 'site': 'Local', 'bay': '8', 'carrier': '', 'serialno': 'XXX', 'owner': '', 'model': 'X343_TA15E1T8A10', 'disk_type': '4', 'blockNum': '17612'}

  • 检测到不一致的用户数据块、请引用 <volume_name> 本地层聚合上的:

[node-01: wafl_exempt12: wafl.raid.incons.userdata:error]: WAFL inconsistent: inconsistent user data block at VBN XXX (vvbn:XXX fbn:XXX level:0) in public inode (fileid:XXX snapid:0 file_type:15 disk_flags:0x8402 error:120 raid_set:1) in volume <volume_name>@vserver:<Vserver_UUID>.

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.