跳转到主内容

运行状况监控器报告 " 集群交换机缺少冗余配置 " 。

Views:
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
hw
Last Updated:

适用场景

  • 所有 FAS 系统
  • 交换集群配置

问题描述

生成运行状况警报,报告 " 集群交换机缺少冗余配置 " 。

 ::> system health alert show -alert-id ClusterSwitchMissing_Alert -instance Node: node1 Monitor: cluster-switch Alert ID: ClusterSwitchMissing_Alert Alerting Resource: cluster1-02 Subsystem: Switch-Health Indication Time: Wed Nov 27 10:22:08 2019 Perceived Severity: Major Probable Cause: Configuration_error Description: Redundant configuration is missing for cluster switches. Corrective Actions: 1) Ensure that a redundant pair of cluster switches exists in the network. 2) Ensure that cluster ports are connected to both switches. 3) Enable the Cisco Discovery Protocol (CDP)/Industy Standard Discovery Protocol(ISDP) on switches, if you previously disabled it. CDP/ISDP is enabled by default. Refer to your switch documentation for instructions. 4) If Data ONTAP cannot automatically discover a switch, use the "system cluster-switch create" command to configure discovery and monitoring of the switch. 

 