HA 组通知(文件系统磁盘故障磁盘架 XX ,托架 YY ,型号 ... ) 错误
适用场景
- 所有 FAS 和 AFF 型号
- ONTAP 9
- 7-模式 Data ONTAP
问题描述
- AutoSupport 报告磁盘出现故障。
HA Group Notification (FILESYSTEM DISK FAILED Shelf 22, Bay 14, Model [X422_HCOBE600A10], S/N [XXXXXXXX]) ERROR
- EMS 消息类似于:
Sun Jul 26 08:22:21 CEST [node_name: raidio_thread: raid.disk.predictiveFailure:error]: Disk /aggregate/plex0/rg2/0a.22.14 Shelf 22 Bay 14 [NETAPP X422_HCOBE600A10 NA02] S/N [XXXXXXXX] UID [xxxxxxxx:xxxxxxxx:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000] reported and it will be copied to a spare and failed
Sun Jul 26 08:22:23 CEST [node_name: config_thread: raid.rg.diskcopy.start:notice]: /aggregate/plex0/rg2: starting disk copy from 0a.22.14 to 4a.22.17. Reason: Disk replace was started..
Sun Jul 26 08:22:23 CEST [node_name: config_thread: raid.config.filesystem.disk.failed:error]: File system Disk /aggregate/plex0/rg2/0a.22.14 Shelf 22 Bay 14 [NETAPP X422_HCOBE600A10 NA02] S/N [XXXXXXXX] UID [xxxxxxxx:xxxxxxxx:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000] failed.
Sun Jul 26 08:22:23 CEST [node_name: disk_admin: disk.failmsg:notice]: Disk 0a.22.14 (XXXXXXXX): Predictive Failure PFA (0x01), ASC(0x5d), ASCQ(0x90), FRU(0x90). 3194641 Disk 0a.22.14 Shelf 22 Bay 14 [NETAPP X422_HCOBE600A10 NA02] S/N [XXXXXXXX] UID [xxxxxxxx:xxxxxxxx:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000]
Sun Jul 26 08:22:23 CEST [node_name: dmgr_thread: raid.notify.on.failure:debug]: Received SDM_NOTIFY_ON_FAILURE for disk uid xxxxxxxx:xxxxxxxx:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000, originating sysid 536877193, with failure reason 1 (failed).
Sun Jul 26 08:22:23 CEST [node_name: config_thread: callhome.fdsk.fault:error]: Call home for FILESYSTEM DISK FAILED Shelf 22, Bay 14, Model [X422_HCOBE600A10], S/N [XXXXXXXX]