跳转到主内容

BIOS升级错误:无法将主映像保存到备份闪存设备

Views:
45
Visibility:
Public
Votes:
1
Category:
fas-systems
Specialty:
HW
Last Updated:

适用场景

  • AFF A300
  • AFF A320
  • AFF A200
  • AFF A220
  • AFF A700s
  • FAS 8200
  • BIOS更新
    • 手动
    • andu

问题描述

New BIOS version: 11.15
New LOADER version: 6.0.14
Enabling write access to the flash ME region...
ME region - write access enabled.
Saving Primary Image to Backup flash device
fail unlocking memory
Failed. -4 bytes written: I/O error
Failed to save Primary Image to Backup flash device. Programming of Primary aborted
Automatic firmware update skipped (update_flash command failed).

Warning: The boot media contains a newer firmware image (11.15).
Please run 'update_flash' at the Loader prompt to update your
system firmware (11.11).

New BIOS version: 11.15
New LOADER version: 6.0.14
Enabling write access to the flash ME region...
ME region - write access enabled.
Saving Primary Image to Backup flash device
-------------------------------------------------------
---------.+**** Flash verify failed. ****
Failed. -4 bytes written: I/O error
Failed to save Primary Image to Backup flash device.  Programming of Primary aborted
*** command status = I/O error(-4)

  • 如果执行自动无中断升级(Automated Non-Disrupanting Upgrade、ANDU)、则升级会  因配对节点而暂停 is not in a "waiting for giveback

::> cluster image show-update-progress 
                       Estimated      Elapsed
Update Phase      Status           Duration     Duration
-------------------- ----------------- --------------- ---------------
Pre-update checks   completed         00:10:00     00:00:35
Data ONTAP updates   paused-on-error      01:23:00     00:37:18
 
Details:
 
Node name       Status       Status Description
-------------------- ----------------- --------------------------------------
node-01      waiting
node-02      failed       Error: Node "node-02" is not in
                    "waiting for giveback" state.
                    Action: Use the "storage failover
                    show" to verify that node
                    "node-02" is in one of the
                    following states: "waiting for
                    giveback" or "connected".

  • 从SP执行system power cycle 不会解析问题描述。

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.