适用场景

  • ONTAP 7-模式
  • ONTAP 9
  • FCP
  • SAN

问题描述

  • 事件日志条目指示FC链路已断开:

5/23/2020 21:11:31  cluster-node1  ERROR scsitarget.ispfct.linkBreak: Link break detected on Fibre Channel target adapter 1b. Firmware status code status1 0x2, status2 0x7, and status4 0x0.


cluster::> network fcp adapter show
           Connection  Port    Admin   Operational
Node      Adapter Established Address   Status  Status
------------ ------- ----------- --------- ------- -----------------------
cluster-node1
       0c    false     0      up    link not connected
cluster-node1
       0d    false     0      up    link not connected
cluster-node1
       1a      true     f0500    up    online
cluster-node1
       1b    true     0      up    link disconnected
cluster-node2
       0c    false     0      up    link not connected
cluster-node2
       0d    false     0      up    link not connected
cluster-node2
       1a    true     f0600    up      online
cluster-node2
       1b    true     f0600    up    online

  • 存储HBA端口仍处于物理连接状态

 