FAS8700/FAS8300/AFA400/AFC400报告(机箱温度过高)错误警告
适用场景
- ONTAP 9
- AFF A400
- AFF C400
- FAS 8300
- FAS 8700
问题描述
- 两个节点上的机箱温度每小时错误消息。示例:
[node_name-01: env_mgr: monitor.temp.unreadable:error]: The controller temperature (LED1 Temp) is not readable.
[node_name-01: env_mgr: monitor.temp.unreadable:error]: The controller temperature (LED2 Temp) is not readable.
[node_name-01: env_mgr: callhome.chassis.hitemp:error]: Call home for CHASSIS OVER TEMPERATURE
[node_name-02: env_mgr: monitor.temp.unreadable:error]: The controller temperature (LED1 Temp) is not readable.
[node_name-02: env_mgr: monitor.temp.unreadable:error]: The controller temperature (LED2 Temp) is not readable.
[node_name-02: env_mgr: callhome.chassis.hitemp:error]: Call home for CHASSIS OVER TEMPERATURE
- 生成的AutoSupport包含:
HA Group Notification (CHASSIS OVER TEMPERATURE) ERROR
- LED1或LED2温度传感器出现故障。示例:
::> system node run -node node_name-01 -command environment chassis list-sensors
Sensor Name State Current Critical Warning Warning Critical
Reading Low Low High High
----------------------------------------------------------------------------------------
...
LED1 Temp failed -- C 0 C 3 C 43 C 46 C
或
::> system node run -node node_name-01 -command environment status chassis
Sensor Name State Current Critical Warning Warning Critical
Reading Low Low High High
-------------------------------------------------------------------------------------------------
LED1 Temp not_available -- C 0 C 3 C 43 C 46 C
LED2 Temp not_available -- C 0 C 3 C 43 C 46 C
No reading
BMC调试日志中LED传感器的""输出。示例:
LED1_Temp | 16h | ns | 12.1 | No Reading
LED2_Temp | 17h | ns | 12.1 | No Reading
LED1_Temp | na | degrees C | na | na | 0.000 | 3.000 | 43.000 | 46.000 | na
LED2_Temp | na | degrees C | na | na | 0.000 | 3.000 | 43.000 | 46.000 | na