跳转到主内容

由于电池传感器不可读,环境关闭

Views:
23
Visibility:
Public
Votes:
0
Category:
fas-systems<a>2008820631.</a>
Specialty:
hw
Last Updated:

适用场景

  • AFF A250
  • ONTAP 9

问题描述

  • 节点突然执行环境关闭。
  • 配对节点会执行接管,在导致关闭的受影响节点上,可能会出现与无法读取的电池传感器相关的错误。
  • 在 EMS 日志中可以看到以下内容:

[node_name:nvmem.battery.unread:EMERGENCY]: The NVMEM battery state cannot be determined because the 'Bat Initial FCC' sensor is unreadable. To prevent data loss, the system will shut down in 5 minutes.
[node_name:nvmem.battery.packInvalid:EMERGENCY]: The incorrect NVMEM battery is installed. Expected part number is 271-00045. To prevent data loss, the system will shut down in 5 minutes.
[node_name:nvmem.battery.unread:EMERGENCY]: The NVMEM battery state cannot be determined because the 'Bat Initial FCC' sensor is unreadable. To prevent data loss, the system will shut down in 5 minutes.
[node_name:callhome.battery.failure:EMERGENCY]: Call home for BATTERY ('Bat Initial FCC' unreadable) CRITICAL.
[node_name:nvmem.battery.packInvalid:EMERGENCY]: The incorrect NVMEM battery is installed. Expected part number is 271-00045. To prevent data loss, the system will shut down in 5 minutes.
[node_name:monitor.shutdown.emergency:EMERGENCY]: Emergency shutdown: Environmental Reason Shutdown (Battery initial FCC failed)


[node_name: env_mgr: nvmem.battery.unread:EMERGENCY]: The NVMEM battery state cannot be determined because the 'Bat Temp' sensor is unreadable. To prevent data loss, the system will shut down in 5 minutes.
[node_name: env_mgr: nvmem.battery.unread:EMERGENCY]: The NVMEM battery state cannot be determined because the 'Bat Volt' sensor is unreadable. To prevent data loss, the system will shut down in 5 minutes.
[node_name: env_mgr: nvmem.battery.unread:EMERGENCY]: The NVMEM battery state cannot be determined because the 'Bat Curr' sensor is unreadable. To prevent data loss, the system will shut down in 5 minutes.
[node_name: env_mgr: nvmem.battery.unread:EMERGENCY]: The NVMEM battery state cannot be determined because the 'Bat Full Cap' sensor is unreadable. To prevent data loss, the system will shut down in 5 minutes.
[node_name: env_mgr: nvmem.battery.unread:EMERGENCY]: The NVMEM battery state cannot be determined because the 'Bat Charge Curr' sensor is unreadable. To prevent data loss, the system will shut down in 5 minutes.
[node_name: env_mgr: nvmem.battery.unread:EMERGENCY]: The NVMEM battery state cannot be determined because the 'Bat Charge Volt' sensor is unreadable. To prevent data loss, the system will shut down in 5 minutes.
[node_name: env_mgr: nvmem.battery.unread:EMERGENCY]: The NVMEM battery state cannot be determined because the 'Bat Initial Fcc' sensor is unreadable. To prevent data loss, the system will shut down in 5 minutes.
[node_name: env_mgr: nvmem.battery.unread:EMERGENCY]: The NVMEM battery state cannot be determined because the 'Bat Dstg Cycles' sensor is unreadable. To prevent data loss, the system will shut down in 5 minutes.
[node_name: env_mgr: nvmem.battery.unread:EMERGENCY]: The NVMEM battery state cannot be determined because the 'Bat Dsg FET Flt' sensor is unreadable. To prevent data loss, the system will shut down in 5 minutes.

  • SP-LATEST-IPMI / system fru show BMC 命令行界面输出:

Bat_Temp      | na  | degrees C   | na   | 0.000 | 0.000 | 5.000 | 60.000 | 75.000 | 127.500   
Bat_Volt      | na  | Volts     | na   | 0.000 | 5.500 | 5.600 | 8.500  | 8.600  | 12.750   
Bat_Curr      | na  | Amps      | na   | na   | na   | na   | 1.200  | 1.520  | 2.540    
Bat_Rem_Cap    | na  | Watts * hour | na   | na   | na   | na   | na    | na    | na     
Bat_Full_Cap    | na  | Watts * hour | na   | na   | na   | na   | na    | na    | na     
Bat_Charge_Curr  | na  | Amps      | na   | na   | na   | na   | 2.200  | 2.300  | 5.100    
Bat_Charge_Volt  | na  | Volts     | na   | na   | na   | na   | 8.900  | 9.000  | 12.750   
Bat_Design_Cap   | na  | Watts * hour | na   | na   | na   | na   | na    | na    | na     
Bat_Initial_Fcc  | na  | Watts * hour | na   | na   | na   | na   | na    | na    | na     
Bat_Dstg_Cycles  | na  | cycles     | na   | na   | 2.000 | 5.000 | na    | na    | na     
Bat_Cycle_Cnt   | na  | cycles     | na   | na   | na   | na   | na    | na    | na     
Bat_Power_Fault  | 0x0 | discrete    | 0x0180| na   | na   | na   | na    | na    | na     
Bat_Dsg_FET_Flt  | na  | discrete    | na   | na   | na   | na   | na    | na    | na     
Bat_Chg_FET_Flt  | na  | discrete    | na   | na   | na   | na   | na    | na    | na     
Bat_Pack_Invalid | na  | discrete    | na   | na   | na   | na   | na    | na    | na

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.