跳转到主内容

Coming soon...New Support-Specific categorization of Knowledge Articles in the NetApp Knowledge Base site to improve navigation, searchability and your self-service journey.

存储设备状态为“ Critical ”(严重)、错误为“ Power Control State : Critical ”(电源控制状态:严重)—检测到电源控制故障

Views:
47
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
hw
Last Updated:

适用于

  • DS14mk4 FC
  • Data ONTAP 8
  • SCSI 存储设备服务( SE )

问题

  • 机柜状态和电源控制在命令 "" 中是关键storage show fault的。

示例:

Enclosure Status: critical
Channel: 12b
Shelf: 1
Shelf Type: DS14-Mk4-FC
Product Serial Number: OPS67734221717E
Module Type: ESH

...

Vendor Unique Element 80-ESH: (ESH HUB)
Element Status         Status Bytes  Status Descriptions
  1 [ESH A]    : OK                01,00,00,03  
  2 [ESH A]    : OK                01,00,00,03  

Vendor Unique Element 84-ESH: (Power Ctrl)
Element Status         Status Bytes  Status Descriptions
  1: CRITICAL          02,86,00,00

  • 电源控制状态为 "incritical - power control fault detected command" environment status"

示例:

Channel: 12b Shelf: 1 Shelf Serial Number: OPS67734221717E
Shelf product id: DS14-Mk4-FC
Module A Serial Number: IMS6981331F5A74  Firmware rev: 14
Module B Serial Number: IMS6981331F5C7B  Firmware rev: 14
Controller A boot time: 2738 days 4 hrs 5 mins 11 secs
Controller B boot time: 2741 days 19 hrs 43 mins 31 secs
Power control state: critical - power control fault detected
Last power control completion status: inconsistent drive status
Timestamp: Sun Jun 28 14:20:44 CST 2020

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

Scan to view the article on your device