EMS 在 FAS8080 上报告 "ic.linkSpeedDegraded"
适用场景
FAS8080
问题描述
- 互连链路上出现链路宽度降级错误
[?] Thu Apr 21 01:00:45 KST [node02: statd: ic.linkSpeedDegraded:error]: HA interconnect: Link speed of link #0 degraded. Current: SDR, expected: QDR.
Data Rate
ib0a 端口的输出为 10Gb/ 秒sysconfig -a
Interconnect Port 1:
Port Name: ib0a
Default GID: fe80:0000:0000:0000:00a0:9800:0034:473c
Base LID: 0x73c
Active MTU: 4096
Data Rate: 10 Gb/s (4X) SDR
Link State: ACTIVE
QSFP Vendor: Molex Inc.
QSFP Part Number: 112-00374+A0
QSFP Type: Active Optical 5m ID:00
QSFP Serial Number: 93AG15024F0583
Interconnect Port 2:
Port Name: ib0b
Default GID: fe80:0000:0000:0000:00a0:9800:0034:473d
Base LID: 0x73d
Active MTU: 4096
Data Rate: 40 Gb/s (4X) QDR
Link State: ACTIVE
QSFP Vendor: Molex Inc.
QSFP Part Number: 112-00374+A0
QSFP Type: Active Optical 5m ID:00
QSFP Serial Number: 93AG16152F0441