跳转到主内容

在 ONTAP 升级期间, FAS2720 上的集群网络端口发生故障

Views:
5
Visibility:
Public
Votes:
0
Category:
fas-systems<a>2009-137445</a>
Specialty:
hw
Last Updated:

适用场景

  • FAS2720
  • FAS2750
  • AFF A220
  • AFF C190
  • ONTAP 升级
  • 无交换机集群

问题描述

  • 其中一个节点完成了更新,并在运行其根聚合时重新启动
  • 配对节点仍在以 "Partial Giveback" 状态运行先前的 ONTAP 版本
  • 在每个节点上,集群网络端口均已关闭:

::*> network port show
Node: node_name_01
                          Speed(Mbps) Health   Health
Port    IPspace    Broadcast Domain Link MTU  Admin/Oper  Status   Status
--------- ------------ ---------------- ---- ---- ----------- -------- ------
...
e0a     Cluster    -         down 9000  auto/auto  -     false
e0b     Cluster    -         down 9000  auto/auto  -     false
...
10 entries were displayed.

  • 自动无中断更新( ANDU )已暂停:

[node_name_02: upgrademgr: upgrademgr.update.pausedErr:error]: The automated update of the cluster has been paused due to the following reason:  Node "node_name_01": Error: {Node "node_name-02" is not in "connected" state after giveback.}, Action: {Use the "storage failover show" command to verify that node "node_name-02" is in the "connected" state.}.

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

Scan to view the article on your device