跳转到主内容

nodeshell中的聚合重复、而clustershell中的聚合不重复

Views:
2
Visibility:
Public
Votes:
0
Category:
fas-systems<a>2009260832</a>
Specialty:
core
Last Updated:

适用场景

  • ONTAP 9

问题描述

  • nodeshell报告聚合出现故障、该聚合与系统上现有运行状况良好的聚合重复。
  • 此不正确的聚合与附加了(1)的正确聚合名称相同。不正确的聚合显示为故障、并由一个磁盘以及可能还有其他未同化的孤立磁盘组成。

示例:

 Aggregate n01_aggr1(1) (failed, mixed_raid_type, partial, hybrid_enabled) (block checksums) Plex /n01_aggr1(1)/plex0 (offline, failed, inactive) RAID group /n01_aggr1(1)/plex0/rg5 (partial, block checksums, raid_dp) RAID Disk Device HA SHELF BAY CHAN Pool Type RPM Used (MB/blks) Phys (MB/blks) --------- ------ ------------- ---- ---- ---- ----- -------------- -------------- dparity FAILED N/A 1695466/ - parity FAILED N/A 1695466/ - data FAILED N/A 1695466/ - data FAILED N/A 1695466/ - data FAILED N/A 1695466/ - data FAILED N/A 1695466/ - data FAILED N/A 1695466/ - data FAILED N/A 1695466/ - data FAILED N/A 1695466/ - data 3b.12.17 3b 12 17 SA:B 0 BSAS 7200 1695466/3472315904 1695759/3472914816 data FAILED N/A 1695466/ - data FAILED N/A 1695466/ - data FAILED N/A 1695466/ - data FAILED N/A 1695466/ - Raid group is missing 13 disks. Plex is missing 11 RAID groups. Unassimilated n01_aggr1(1) disks RAID Disk Device HA SHELF BAY CHAN Pool Type RPM Used (MB/blks) Phys (MB/blks) --------- ------ ------------- ---- ---- ---- ----- -------------- -------------- orphaned 3b.12.9 3b 12 9 SA:B 0 BSAS 7200 1695466/3472315904 1695759/3472914816 orphaned 3b.13.1 3b 13 1 SA:B 0 BSAS 7200 1695466/3472315904 1695759/3472914816
  • Vreport还会显示差异。

示例:

对象类型聚合
对象N01_aggr1 (xxxxxxx-xxxx-xxxx-xxxx-xxxxxxxxxxxx)
节点名称:节点01
聚合UUID:<xxxxxxx-xxxx-xxxx-xxxx-xxxxxxxxxxxxxxxx>
聚合状态:故障
聚合RAID状态:混合RAID_type、部分、混合启用的
聚合HA策略:SFO
为聚合根: false
是复合聚合:仅
WAFL 中存在差异的原因为false

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.