磁盘为7200 RPM、但在"sysconfig -r"中显示为15000 RPM

Views:
24
Visibility:
Public
Votes:
0
Category:
disk-drives<a>1035556</a>
Specialty:
hw
Last Updated:

状态信息

适用场景

  • ONTAP 9.1
  • Data ONTAP 8

问题描述

磁盘速度为7200 RPM、但在"sysconfig -r"中、某些磁盘显示为15000 RPM。

示例:

Aggregate aggr0 (online, raid_dp, degraded) (block checksums)
  Plex /aggr0/plex0 (online, normal, active)
    RAID group /aggr0/plex0/rg0 (double degraded, block checksums)

      RAID Disk Device          HA  SHELF BAY CHAN Pool Type  RPM  Used (MB/blks)    Phys (MB/blks)
      --------- ------          ------------- ---- ---- ---- ----- --------------    --------------
      dparity   0a.00.21        0a    0   21  SA:B   0  FSAS  7200 3807816/7798408704 3815447/7814037168
      parity    FAILED                  N/A                        3807816/ -
      data      FAILED                  N/A                        3807816/ -

Pool0 spare disks

RAID Disk       Device          HA  SHELF BAY CHAN Pool Type  RPM  Used (MB/blks)    Phys (MB/blks)
---------       ------          ------------- ---- ---- ---- ----- --------------    --------------
Spare disks for block checksum
spare           0a.00.22        0a    0   22  SA:B   0   SAS 15000 3807816/7798408704 3815447/7814037168
spare           0a.00.23        0a    0   23  SA:B   0   SAS 15000 3807816/7798408704 3815447/7814037168

 