跳转到主内容

HA 对中的一个节点无法在两个路径上识别磁盘

Views:
12
Visibility:
Public
Votes:
0
Category:
disk-shelves
Specialty:
hw
Last Updated:

适用场景

  • FAS2552
  • DS4246

问题描述

  • 一个节点的两个路径上都缺少磁盘,而另一个节点则不缺少磁盘。
  • 硬重置到两个节点的适配器中的磁盘。EMS 错误 示例

Fri May 21 12:31:18 CEST [Filer-01: pmcsas_asyncd_0: sas.adapter.debug:info]: params: {'debug_string': 'ABORT TASK of device 0b.01.15 Tag 0x6f570022 failed (retries exhausted) or timed out -- scheduling HARD LINK RESET', 'adapterName': '0a'}
Fri May 21 12:31:20 CEST [Filer-01: pmcsas_admin_0: sas.adapter.debug:info]: params: {'debug_string': 'SSP_EVENT 0x30 on 0b.01.15, TAG 0x730a00b8, INIT_TAG 0x80ba: target reset', 'adapterName': '0a'}
Fri May 21 12:31:20 CEST [Filer-01: pmcsas_admin_0: sas.adapter.debug:info]: params: {'debug_string': 'ABORT TASK on device 0b.01.15 Tag 0x730a00b8', 'adapterName': '0a'}
Fri May 21 12:31:32 CEST [Filer-01: pmcsas_asyncd_0: sas.adapter.debug:info]: params: {'debug_string': 'ABORT TASK of device 0b.01.15 Tag 0x730a00b8 failed (retries exhausted) or timed out -- scheduling HARD LINK RESET', 'adapterName': '0a'}
Fri May 21 12:31:33 CEST [Filer-01: scsi_cmdblk_strthr_admin: scsi.cmd.pastTimeToLive:error]: Disk device 0b.01.15: request failed after try #1: cdb 0x12.
Fri May 21 12:30:56 CEST [Filer-02: pmcsas_admin_0: sas.adapter.debug:info]: params: {'debug_string': 'SSP_EVENT 0x30 on 0a.01.15, TAG 0x40f30033, INIT_TAG 0x444f: target reset', 'adapterName': '0a'}
Fri May 21 12:30:56 CEST [Filer-02: pmcsas_admin_0: sas.adapter.debug:info]: params: {'debug_string': 'ABORT TASK on device 0a.01.15 Tag 0x40f30033', 'adapterName': '0a'}
Fri May 21 12:31:08 CEST [Filer-02: pmcsas_asyncd_0: sas.adapter.debug:info]: params: {'debug_string': 'ABORT TASK of device 0a.01.15 Tag 0x40f30033 failed (retries exhausted) or timed out -- scheduling HARD LINK RESET', 'adapterName': '0a'}

  • 重新安装和更换磁盘不能解决问题
  • 重新安装和更换 IOM 不会解决问题描述问题。

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.

 

  • 这篇文章对您有帮助吗?