跳转到主内容

控制器无法启动,并显示错误 "Detected FIPS-certed Encrypting disk x.x.x"

Views:
4
Visibility:
Public
Votes:
0
Category:
fas-systems<a>启动设备</a><a>2008564955</a>
Specialty:
hw
Last Updated:

适用场景

  • FAS
  • AFF
  • ONTAP 9
  • FIPS 驱动器
  • NSE 驱动器

问题描述

  • 启动ONTAP 后、所有驱动器均显示FAILED。
  • 例如、在启动到维护模式后 sysconfig -v 、如下所示:

        slot 0: SAS Host Adapter 0a (PMC-Sierra PM8070 rev. C, SAS, <UP>)
                Firmware rev:       03.08.09.00
                Base WWN:           5:00a098:0038a6d:30
                Phy State:          [0] Enabled, 12.0 Gb/s
                                    [1] Enabled, 12.0 Gb/s
                                    [2] Enabled, 12.0 Gb/s
                                    [3] Enabled, 12.0 Gb/s
                Mini-SAS HD Vendor:        Amphenol
                Mini-SAS HD Part Number:   112-00435+A0
                Mini-SAS HD Type:          Passive Copper (unequalized) 0.5m ID:01
                Mini-SAS HD Serial Number: APF16454005221
                 ID     Vendor   Model            FW    Size
                00.0 : NETAPP   X438_1625400MCSG NA04 381.3GB (781422768 520B/sect) (Failed)
                00.1 : NETAPP   X438_1625400MCSG NA04 381.3GB (781422768 520B/sect) (Failed)
                00.2 : NETAPP   X438_1625400MCSG NA04 381.3GB (781422768 520B/sect) (Failed)
                00.3 : NETAPP   X438_1625400MCSG NA04 381.3GB (781422768 520B/sect) (Failed)
                00.4 : NETAPP   X438_1625400MCSG NA04 381.3GB (781422768 520B/sect) (Failed)
                00.5 : NETAPP   X438_1625400MCSG NA04 381.3GB (781422768 520B/sect) (Failed)
                00.6 : NETAPP   X438_1625400MCSG NA04 381.3GB (781422768 520B/sect) (Failed)
                00.7 : NETAPP   X438_1625400MCSG NA04 381.3GB (781422768 520B/sect) (Failed)
                00.8 : NETAPP   X438_1625400MCSG NA04 381.3GB (781422768 520B/sect) (Failed)
                00.9 : NETAPP   X438_1625400MCSG NA04 381.3GB (781422768 520B/sect) (Failed)
                00.10: NETAPP   X438_1625400MCSG NA04 381.3GB (781422768 520B/sect) (Failed)
                00.11: NETAPP   X438_1625400MCSG NA04 381.3GB (781422768 520B/sect) (Failed)

  • 启动时,将显示以下消息:
Dec 01 14:34:15 [localhost:disk.encryptNoSupport:error]: Detected FIPS-certified encrypting disk 0b.00.3, but bootarg.storageencryption.support indicates that FIPS disks should not be present. 24 of 24 disks checked are FIPS disks.
  • 如果已配置HA、则系统可以继续启动、直到 Waiting for giveback:

Waiting for giveback...(Press Ctrl-C to abort wait)Entering FM state:5 because mbFound:0 local in headswap:0
Entering FM state:5 because mbFound:0 local in headswap:0
Entering FM state:5 because mbFound:0 local in headswap:0
....

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.