集群交换机日志收集会在禁用后发出错误的运行状况警报
适用场景
收集集群交换机日志
问题描述
- 系统会收到运行状况警报,指示交换机日志收集登录失败:
Alert ID: SwitchAccess_Alert
Subsystem Switch-Health
Probable Cause Login_attempts_failed
Corrective Actions
1) To set up public SSH key authentication on the cluster switch,
。
run the "system cluster-switch log setup-password" command.
ONTAP requires one-time use of the cluster switch's administrative login credentials
to set up the public SSH key for ONTAP access.
The administrative credentials will be discarded after the setup command is complete.
2) If public SSH key authentication is already configured, log in to the cluster switch
with administrative credentials from an SSH host or serial console to investigate the login failures.
3) To disable tech-support log collection, run the "system cluster-switch log disable-collection" command