跳转到主内容

NetApp_Insight_2020.png 

机箱电源已降级,并显示 "PSU 温度警告下限 "

Views:
6
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
hw
Last Updated:

适用于

  • AFF
  • FAS

问题

  • 机箱电源降级 AutoSupport 仍会发出警报,并在降级 / 正常之间切换。

HA Group Notification (CHASSIS POWER DEGRADED: Power Supply Status Critical: PSU1.) ERROR

HA Group Notification (CHASSIS POWER SUPPLY DEGRADED: PS 1) ERROR

HA Group Notification (CHASSIS POWER SUPPLY OK: PS 1) NOTICE

HA Group Notification (CHASSIS POWER DEGRADED: Power Supply Status Critical: PSU2.) ERROR

HA Group Notification (CHASSIS POWER SUPPLY DEGRADED: PS 2) ERROR

HA Group Notification (CHASSIS POWER SUPPLY OK: PS 2) NOTICE

  • EMS 错误包括温度警报:
[?] Sat Aug 08 14:15:01 EDT [node-01: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU1 Temperature is Warning Low (4 C)
[?] Sat Aug 08 14:15:03 EDT [node-01: power_low_monitor: monitor.chassisPower.degraded:alert]: Chassis power is degraded: Power Supply Status Critical: PSU1.
[?] Sat Aug 08 14:17:44 EDT [node-01: env_mgr: monitor.chassisPowerSupply.ok:info]: Chassis power supply 1 is OK.
[?] Sat Aug 08 14:17:53 EDT [node-01: power_low_monitor: monitor.chassisPowerSupplies.ok:info]: Chassis power supplies OK.
  • 其他机箱 PSU ,集群中的其他节点和磁盘架上的温度均较低,并接近警告阈值下限。

 