跳转到主内容

P3.3v BATT"严重"低"或"高"

Views:
25
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
hw
Last Updated:

适用场景

FAS / AFF系统

问题描述

  • EMS日志报告""P3.3V BATT is critical low/high错误。
[env_mgr: monitor.chassispower.degraded:ALERT]: Chassis power is degraded: Sensor detecting voltage anomalies.
[env_mgr: monitor.chassispower.degraded:ALERT]: Chassis power is degraded: P3.3V BATT is critical low (16 mV).
[env_mgr: monitor.chassispower.ok:NOTICE]: Chassis power is OK.
[env_mgr: monitor.chassispower.degraded:ALERT]: Chassis power is degraded: P3.3V BATT is critical high (4064 mV).
[env_mgr: monitor.chassispower.ok:NOTICE]: Chassis power is OK.
 
  • SP-LATEST-IPMI"日志中、RTC电池的状态为正常值。

===SP-LATEST-IPMI===

/usr/local/bin/ipmi sensors
===============================
Sensor Name    |
Current   | Unit     | Status    | LCR     | LNC     | UNC     |
UCR
-----------------+------------+------------+------------+-----------+-----------+-----------+-----------
P3V3_BATT     | 0.160    | Volts    | ok      | 0.016    | 0.032    | 4.048    | 4.064    

/usr/local/bin/environ -show_all
================================
Sensor Name        State      Current   Critical    Warning    Warning
Critical                     Reading     Low      Low      High
High
-------------------------------------------------------------------------------------------------
P3.3V BATT normal      160 mV     16 mV     32 mV    4048 mV    4064 mV

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.

 

  • 这篇文章对您有帮助吗?