跳转到主内容

在接管后,请致电主目录以查看磁盘冗余失败警报

Views:
1
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
hw
Last Updated:

适用场景

  • 8.2.5P5 7- 模式
  • FAS2552

问题描述

  • EMS log show Call home for DISK REDUNDANCY FAILED

[?] Sun Jul 25 09:59:00 CST [Node_B: dsa_disc: shelf.config.tospha:info]: System has transitioned to single path HA attached storage
[?] Sun Jul 25 09:59:00 CST [Node_B: dsa_disc: callhome.dsk.redun.fault:error]: Call home for DISK REDUNDANCY FAILED

 

  • 端口 0b 脱机:

slot 0: SAS Host Adapter 0b (PMC-Sierra PM8001 rev. C, SAS, <OFFLINE (hard)>)
        Firmware rev:     01.12.09.00
        Base WWN:      x:xxxxx:xxxxxxx:xx
        Phy State:      [4] Enabled, Rate unknown
                  [5] Enabled, Rate unknown
                  [6] Enabled, Rate unknown
                  [7] Enabled, Rate unknown

 

  • EMS 日志具有 error information about port 0b :

[?] Sun Jul 25 09:43:16 CST [Node_B: pmcsas_intrd_0: sas.port.down:warning]: SAS port "0b" went down.

[?] Sun Jul 25 09:43:47 CST [Node_B: sinai_link_mgr: cf.ic.sbb:debug]: HA interconnect: SBB Compatibility Event. No compatible partner node found. The interconnect device has been disabled.
[?] Sun Jul 25 09:44:02 CST [Node_B: pmcsas_timeout_0: sas.adapter.debug:info]: params: {'debug_string': 'Link down too long ... offlining', 'adapterName': '0b'}
[?] Sun Jul 25 09:44:02 CST [Node_B: pmcsas_timeout_0: sas.link.error:error]: Could not recover link on SAS adapter 0b after 45 seconds. Offlining the adapter.
[?] Sun Jul 25 09:44:02 CST [Node_B: pmcsas_asyncd_0: sas.adapter.debug:info]: params: {'debug_string': 'pmcsas_asyncd_offline', 'adapterName': '0b'}

 