跳转到主内容

请致电主页了解关键电池(不存在) FAS27xx 和 AFF A220

Views:
4
Visibility:
Public
Votes:
0
Category:
aff-series<a>2008704035</a>
Specialty:
hw
Last Updated:

适用场景

  • AFF A220
  • AFF C190
  • FAS2750
  • FAS2720

问题描述

  • 启动时的错误报告:
WARNING: The battery is unfit to retain data during a power outage. This is likely because the battery is discharged but could be due to other temporary conditions. When the battery is ready, the boot process will complete and services will be engaged. To override this delay, press 'c' followed by 'Enter

Mar 24 06:49:59 [node:callhome.battery.failure:EMERGENCY]: Call home for BATTERY (not present) CRITICAL.

Mar 24 06:51:00 [node:nvmem.battery.notPresent:ALERT]: The NVMEM battery is not present. To prevent data loss, the system will shut down in 5 minutes.

  • 系统无法识别电池组:

::> system node environment sensors show

Bat_Temp      | na     | degrees C  | na      | 0.000    | 5.000    | 56.000   | 60.000   
Bat_Volt      | na     | Volts    | na      | 5.500    | 5.600    | 8.500    | 8.600    
Bat_Curr      | na     | Amps     | na      | na     | na     | 1.520    | 1.800    
Bat_Rem_Cap    | na     | Amps * hour | na      | na     | na     | na     | na     
Bat_Full_Cap    | na     | Amps * hour | na      | na     | na     | na     | na     
Bat_Charge_Curr  | na     | Amps     | na      | na     | na     | 2.400    | 2.900    
Bat_Charge_Volt  | na     | Volts    | na      | na     | na     | 8.900    | 9.000    
Bat_Design_Cap   | na     | Amps * hour | na      | na     | na     | na     | na     
Bat_Initial_Fcc  | na     | Amps * hour | na      | na     | na     | na     | na     
Bat_Average_Temp | na     | degrees C  | na      | na     | na     | na     | na     
Bat_Rem_Cap_off  | na     | Amps * hour | na      | na     | na     | na     | na     
Bat_Dstg_Cycles  | na     | cycles    | na      | 2.000    | 5.000    | na     | na     
Bat_Power_Fault  | 0x0     | discrete   | Asserted   | na     | na     | na     | na     
Bat_Dsg_FET_Flt  | na     | discrete   | na      | na     | na     | na     | na     
Bat_Chg_FET_Flt  | na     | discrete   | na      | na     | na     | na     | na     
Bat_Pack_Invalid | na     | discrete   | na      | na     | na     | na     | na     
Bat_Cycle_Cnt   | na     | cycles    | na      | na     | na     | na     | na     
Bat_Lrn_Active   | na     | discrete   | na      | na     | na     | na     | na    

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.