在服务处理器版本更新期间出现机箱风扇 FRU 失败警告
适用场景
- FAS8200
- 服务处理器( SP ) 5.10
问题描述
- SP 版本更新到 5.10 期间出现机箱风扇 FRU 失败警告。
示例:
Jan 6 17:09:33 (none) env_mgr[1476]: Payload action: fruinfo_get(0, FRU_Fan3)
Jan 6 17:09:33 (none) : [360 INFO]handle_ipmi_query: Server Error: Server Is Busy
Jan 6 17:09:33 (none) : [360 INFO]Error in handle_ipmi_query()
Jan 6 17:09:33 (none) : [360 INFO]Failed to Send Message to SPEM
Jan 6 17:09:33 (none) orftp_sender_splog[697]: system() returned ret1 = 0, ret2 = 0
Jan 6 17:09:33 (none) last message repeated 4 times
Jan 6 17:09:34 (none) env_mgr[1476]: Payload EMS: EMS_callhome_c_fan_fru_fault(CHASSIS FAN FRU FAILED: SysFan3 F1)
Jan 6 17:09:34 (none) env_mgr[1476]: Payload EMS: EMS_monitor_chassisFan_stop(SysFan3 F1 (0 RPM))
Jan 6 17:09:34 (none) env_mgr[1476]: Payload action: update_fru_state(0, FRU_Fan3)
Jan 6 17:09:34 (none) env_mgr[1476]: Payload action: splog_get(1, (null))
Jan 6 17:09:34 (none) env_mgr[1476]: Payload EMS: EMS_callhome_c_fan_fru_fault(CHASSIS FAN FRU FAILED: SysFan3 F2)
- SP 更新后,风扇 FRU 状态正常。