跳转到主内容

由于系统输入断电,两个节点频繁重新启动

Views:
7
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
hw
Last Updated:

适用于

  • FAS8200 单机箱 HA 对

问题

  • 两个节点会在不同时间频繁重新启动
  • SP 日志显示 " 系统输入电源丢失 "
 
[IPMI.notice]: ab01 | 02 | EVT: 01500000 | P12V_STBY_Curr | Assertion Event, "Lower Non-critical going low "
[IPMI.notice]: ac01 | 02 | EVT: 01520000 | P12V_STBY_Curr | Assertion Event, "Lower Critical going low "
[SysFW.notice]: Destage is started
[SP.critical]: Filer Reboots
[Trap Event.critical]: hwassist abnormal_reboot (28)
[IPMI.notice]: ad01 | 02 | EVT: 01508080 | Bat_Curr | Assertion Event, "Lower Non-critical going low "
[IPMI.notice]: ae01 | 02 | EVT: 01528080 | Bat_Curr | Assertion Event, "Lower Critical going low "
[SysFW.notice]: Time completing destage: 38 seconds
[SP.emergency]: System input power lost
 

 