跳转到主内容

从1343620关闭后、两个脱机节点均无法启动

Views:
1
Visibility:
Public
Votes:
0
Category:
fas-systems<a>2009-262561</a>
Specialty:
hw
Last Updated:

适用场景

  • ONTAP 9

问题描述

  • 在BMC更新期间、控制器无响应并根据错误 1343620的症状重新启动
  • 在发生崩溃之前、Active IQ AutoSupport 警报包括:
HA Group Notification (SP HBT MISSED) NOTICE
HA Group Notification (SP HBT STOPPED) ALERT
  • 两个节点都会在EMS中报告以下关闭事件:

[cluster-01: env_mgr: sp.ipmi.lost.shutdown:EMERGENCY]: SP heartbeat stopped and cannot be recovered. To prevent hardware damage and data loss, the system will shut down in 10 minutes.

  • 登录到BMC系统控制台或串行控制台连接表示一个节点停留在启动环路中:
PANIC: NVRAM contents are invalid...
  • 配对节点在关闭期间发生崩溃、无法启动、 Waiting for reservations to clear因为配对节点已接管并自行关闭
  • 配对系统崩溃字符串:
Shutdown taking longer than 930 seconds in process nodewatchdog on release 9.10.1P4 (C)

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.