适用场景

  • FAS8300
  • BMC 固件 13.5.

问题描述

  • 系统将生成以下 AutoSupport 警报
Call home for BATTERY (wrong charge) WARNING.
 
  • 在 EMS 日志中可以看到以下消息
[Node-01: env_mgr: nvmem.battery.wrongCharge:alert]: The NVMEM battery charger is charging the battery even though the battery is not requesting to be charged. To prevent data loss, the system will shut down in 24 hours.
[Node-01: env_mgr: callhome.battery.warning:alert]: Call home for BATTERY (wrong charge) WARNING.
[Node-01: env_mgr: nvmem.battery.normalCharge:notice]: The NVMEM battery charging status is normal.
[Node-01: env_mgr: monitor.shutdown.cancel:notice]: Automatic shutdown sequence canceled.
 
  • BMC 固件已升级到 13.5  
    • NVMEM 电池消息不再显示
  • 仍会记录以下消息:
Sun Aug 22 08:46:18 +0200 [Node-01: env_mgr: monitor.shutdown.cancel:notice]: Automatic shutdown sequence canceled.
Sun Aug 22 09:46:19 +0200 [Node-01: env_mgr: monitor.shutdown.cancel:notice]: Automatic shutdown sequence canceled.
Sun Aug 22 10:46:19 +0200 [Node-01: env_mgr: monitor.shutdown.cancel:notice]: Automatic shutdown sequence canceled