跳转到主内容

更换 PSU 后,由于机箱故障,警示 LED 仍会出现导线

Views:
6
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
hw
Last Updated:

适用于

FAS8040

问题

  • 报告了有关机箱电源( PSU )损坏的以下警报:
    CHASSIS POWER SUPPLY NEED TO BE REPLACED: PS 2) WARNING
  • EMS 日志文件
    [env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 2 is degraded: PSU2 Power Output has failed
    [env_mgr: callhome.chassis.ps.replace:error]: Call home for CHASSIS POWER SUPPLY NEED TO BE REPLACED: PS 2
  • SP 最新事件日志文件
    Record 305:  [Agent.notice]: 561.610: 14 : Attention LED (at Midplane) asserted
    Record 306:  [Agent.notice]: 141.633: 14 : Attention LED (at Midplane) de-asserted
    Record 308:  [Agent.notice]: 538.865: 4 : AC Power Loss Signal PSU2 de-asserted
    Record 309:  [Agent.notice]: 661.755: 6 : DC Power OK PSU2 de-asserted
    Record 310:  [Agent.notice]: 661.760: 10 : Power Supply Fault LED PSU2 asserted
    Record 311:  [Agent.notice]: 774.741: 14 : Attention LED (at Midplane) asserted
    Record 312: [IPMI.notice]: 3500 | 02 | EVT: 0300ffff | PSU2_Pwr_In_OK | Assertion Event, "State Deasserted"
     
  • 已更换 PSU 并出现电源错误 请保留该电源

 