跳转到主内容

ATTO 7500N FibreBridge 重新启动时出现不可纠正的内存错误

Views:
19
Visibility:
Public
Votes:
0
Category:
metrocluster
Specialty:
metrocluster
Last Updated:

适用场景

  • MetroCluster
  • ATTO 7500N FibreBridge

问题描述

ATTO 网桥重新启动时出现不可纠正的内存错误。

  • 单位错误:

037784 05:30:33 03/29/17 CRIT ECC Uncorrected Single-bit error detected. D:1 S:0e6d6607
037787 05:30:33 03/29/17 CRIT Software Interrupt Exception Detected (SWI) (025D)
037794 00:00:02 01/01/00 INFO Reset.  HW Code: Software Warm
037795 00:00:02 01/01/00 INFO Reset.  Reason: Critical Hardware Error Detected

 

  • 多位错误:

0070B5 07:38:21 06/15/20 CRIT ECC Multi-bit error detected. Addr:03761bc0 STS:09
0070C7 07:38:21 06/15/20 INFO 0030a0c8<-003f1b10 | SP[00a220c0] FP[00a220c0]
0070C8 07:38:21 06/15/20 INFO Exception occurred. Possible redundant preceding log entries
0070C9 00:00:05 01/01/00 INFO Reset. HW Code: Software Warm
0070CA 00:00:05 01/01/00 INFO Reset. Reason: Critical Hardware Error Detected

 