跳转到主内容

AFF A400/FAS8300/FAS4700关闭、并显示nvme.bentaly.currentHigh或NO CHARGE警报

Views:
31
Visibility:
Public
Votes:
0
Category:
aff-series<a>2009-164465</a>
Specialty:
hw
Last Updated:

适用场景

  • AFF A400
  • FAS8300
  • FAS8700
  • ONTAP 9

问题描述

症状
  • 在关闭节点之前、系统会报告以下错误:

Sun Nov 26 18:06:47 +0900 [cluster-01: env_mgr: nvmem.battery.noCharge:alert]: The NVMEM battery is requesting to be charged but the charger is not charging the battery. To prevent data loss, the system will shut down in 20 minutes.
Sun Nov 26 18:26:47 +0900 [cluster-01: env_mgr: monitor.shutdown.emergency:EMERGENCY]: Emergency shutdown: Environmental Reason Shutdown (Battery not charging)

  • 关闭之前、节点可能还会报告EMS日志中存在高电流:
Tue May 10 06:47:09 -0400 [cluster-01: env_mgr: nvmem.battery.currentHigh:EMERGENCY]: The NVMEM battery current is critically high (1725 mA). To prevent data loss, the system will shut down in 5 minutes.
  • 可能会显示以下AutoSupport类型:

HA Group Notification from cluster1-01 (BATTERY (no charge)) EMERGENCY

[?] Sun May 28 09:22:50 -0500 [cluster-01: env_mgr: nvmem.battery.capLowCrit:EMERGENCY]: The NVMEM battery capacity is critically low (0 cycles). To prevent data loss, the system will shut down in 20 minutes.
[?] Sun May 28 09:42:20 -0500 [cluster-01: env_mgr: monitor.shutdown.emergency:EMERGENCY]: Emergency shutdown: Environmental Reason Shutdown (Battery remain capacity critical)

确认

要确认问题描述、请使用以下方法之一。

通过BMC
  1. 执行以下命令:

BMC cluster1-01> system battery show

  1. 在结果中、确认以下内容:
    1. 当前 字段显示 “0 mA”
    2. “ Rel示范 介入”字段显示在71%以下
    3. 充电当前 字段显示 “1000 mA”
通过AutoSupport
  1. 打开标题为 “Battery (No)(电池(无电量))”的AutoSupport
  2. 导航到 SP-latest-统计信息 部分。
  3. 在输出中 确认以下内容:
    1. 当前 字段显示 “0 mA”
    2. “ Rel示范 介入”字段显示在71%以下
    3. 充电当前 字段显示 “1000 mA”
  4. 导航到 平台传感器.XML 部分。
  5. 在输出中, 确认以下一项或多项显示为 failed 或 fault:
    1. DBlade蓄电池电压
    2. 电池充电失败?
    3. 电池充电
    4. 蝙蝠充电状态

 

 

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.