跳转到主内容

AF-A700/FAS9000 报告 NVRAM 启动错误消息,但上显示 LED 无实际错误

Views:
36
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
hw
Last Updated:

适用于

  • FAS9000

  • AFF A700  

问题

  • 在 FAS9000 或 AFF A700 中更换 NVDIMM 后,系统仍报告: 

     ::> system controller service-event show -instance Node: NODE_NAME Service Event ID: 1 Location: NVDIMM 1 on PCI 6 Description: NVDIMM1:UECC detected Timestamp: Wed May 30 12:20:03 2018 Node: NODE_NAME Service Event ID:2 Location: NVDIMM 2 on PCI6 Description: NVDIMM2: UECC detected Timestamp: Wed May 30 12:20:04 2018 2 entries were displayed. 
  • 启动过程消息,在控制台日志中: 

================ Log #9 start time Tue Jun 5 14:57:30 2018 NetAppData ONTAP 9.3P4 ******************************************************* WARNING: The NVRAMDIMM1 has caused UECC in the past. Please replace it as soon as possible!!! *************************** WARNING: The NVRAM DIMM2 has caused UECC in the past. Please replace it as soon as possible!!! ****************************************************** 

  • SP 事件:  

Record 2434: Mon Nov 05 16:34:50.052098 2018 [IPMI.notice]: d001 | 02 |EVT: ef02ffff | NVS_Status | Deassertion Event, "Fault"

Record 141: Mon Dec 17 15:42:02.523180 2018 [IPMI.notice]: ac02 | 02 |EVT: 6f02ffff | NVS_Status | Assertion Event, "Fault" < - - - After the power off/on 

  • SP 事件: 

SP NODE_NAME> system service-event show
ID FRU Description Fault
Reason
--------------------------- -------
-----------
1 NVDIMM 1 on PCI 6
NVDIMM1: UECC detected
2 NVDIMM 2 on PCI 6
NVDIMM2: UECCdetected
Fault Lights On:
/chassis-1
PCI 6
NVDIMM 1 on PCI 6
NVDIMM 2 on PCI 6

  • EMS 未报告 UECC/NVRAM 消息 日志

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

Scan to view the article on your device