问题描述

  • 在 FAS9000 或 AFF A700 中更换 NVDIMM 后,系统仍报告: 

    ::> system controller service-event show -instance Node: NODE_NAME Service Event ID: 1 Location: NVDIMM 1 on PCI 6 Description: NVDIMM1:UECC detected Timestamp: Wed May 30 12:20:03 2018 Node: NODE_NAME Service Event ID:2 Location: NVDIMM 2 on PCI6 Description: NVDIMM2: UECC detected Timestamp: Wed May 30 12:20:04 2018 2 entries were displayed.
  • 启动过程消息,在控制台日志中: 

================ Log #9 start time Tue Jun 5 14:57:30 2018 NetAppData ONTAP 9.3P4 ******************************************************* WARNING: The NVRAM DIMM1 has caused UECC in the past. Please replace it as soon as possible!!! *************************** WARNING: The NVRAM DIMM2 has caused UECC in the past. Please replace it as soon as possible!!! ****************************************************** 

  • SP 事件:  

Record 2434: Mon Nov 05 16:34:50.052098 2018 [IPMI.notice]: d001 | 02 |EVT: ef02ffff | NVS_Status | Deassertion Event, "Fault"

Record 141: Mon Dec 17 15:42:02.523180 2018 [IPMI.notice]: ac02 | 02 |EVT: 6f02ffff | NVS_Status | Assertion Event, "Fault" < - - - After the power off/on 

  • SP 事件: 

SP NODE_NAME> system service-event show
ID FRU Description Fault
Reason
--------------------------- -------
-----------
1 NVDIMM 1 on PCI 6
NVDIMM1: UECC detected
2 NVDIMM 2 on PCI 6
NVDIMM2: UECCdetected
Fault Lights On:
/chassis-1
PCI 6
NVDIMM 1 on PCI 6
NVDIMM 2 on PCI 6

  • EMS 未报告 UECC/NVRAM 消息 日志

 

 

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.