适用场景

DS224C 磁盘架

问题描述

  • EMS.log 报告两个磁盘架 ACP 模块出现故障
ses.status.ACPError:alert]: DS224-12 (S/N XXXXXXXXXXXXXXX) shelf 24 on channel 9c ACP Processor error for SAS shelf ACP processor 1: critical status ; Alternate Control Path hardware failed This module is on the rear of the shelf at the top left, on shelf module A.
ses.status.ACPError:alert]: DS224-12 (S/N XXXXXXXXXXXXXXX) shelf 24 on channel 9c ACP Processor error for SAS shelf ACP processor 2: critical status ; Alternate Control Path hardware failed This module is on the rear of the shelf at the top right, on shelf module B.
monitor.shelf.fault:alert]: Critical fault reported on disk storage shelf attached to channel 1b. Check fans, power supplies, disks, and temperature sensors.
callhome.shlf.fault:error]: Call home for SHELF_FAULT
  • CLI 会报告两个 ACP 模块的严重状态:
Cluster::> system node run -node <node name> -command storage show fault -v
Enclosure Status: critical
Channel: 1b
Shelf: 24
Shelf Type: DS224-12
Product Serial Number: XXXXXXXXXXXXXXX
Module Type: IOM12
Vendor Unique Element 85-IOM12: (ACP)
Element Status Status Bytes Status Descriptions
1 [IOM12 A] : CRITICAL 02,18,00,40 NO ACPP, INBACP, FAIL
2 [IOM12 B] : CRITICAL 02,18,00,40 NO ACPP, INBACP, FAIL
  • 已禁用并重新启用 ACP
  • 已重新拔插磁盘架模块
  • 已更换磁盘架模块
  • 磁盘架已重新启动