7- 模式节点执行紧急关闭并发生接管
适用场景
- 7-模式
- 服务处理器 (SP)
问题描述
- 7- 模式节点意外关闭
- SP 版本低于 SP 1.6 , 2.4 , 3.2 , 4.0 , 5.0
- SP 未在 300 天后重新启动
- 以下是关闭之前看到的事件消息示例:
env_mgr: monitor.temp.unreadable:info]: The controller temperature (In Flow Temp) is not readable.
env_mgr: monitor.temp.unreadable:info]: The controller temperature (PCI Riser_R Temp) is not readable.
env_mgr: monitor.temp.unreadable:info]: The controller temperature (Smart Bat Temp) is not readable.
env_mgr: monitor.power.unreadable:info]: A power sensor 12V STBY in the controller module is not readable.
env_mgr: monitor.power.unreadable:info]: A power sensor 12V STBY Curr in the controller module is not readable.
env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU1 Fan1 Speed is Unreadable
env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU1 Fan1 Fault is Unreadable
monitor.shutdown.emergency:EMERGENCY]: Emergency shutdown: Environmental Reason Shutdown (Temperature critical)