system controller memory dimm show 命令未反映 CECC 错误计数
适用场景
- ONTAP 9.5及更高版本
- ONTAP 9.4P6及更高版本9.4
- ONTAP 9.3P11及更高版本9.3
- ONTAP 9.1P18及更高版本9.1
问题描述
system controller memory dimm show
""命令未反映CECC错误计数。
::*> system controller memory dimm show -fields cecc-count ,uecc-count ,status
DIMM UECC CECC Alert CPU Slot
Node Name Count Count Method Socket Channel Number Status
------------- ------- ------- ------ ------ ------ ------- ------ --------
Fas8200-01
DIMM-1 0 0 bucket 0 0 0 ok
DIMM-2 0 0 bucket 0 0 1 ok
DIMM-3 0 0 bucket 0 1 0 ok
DIMM-4 0 0 bucket 0 1 1 ok
system node show-memory-errors
""和MEMERR-VERBOSE.XML
日志显示增加的CECC计数。
::*> system node show-memory-errors
Correctable ECC Memory Errors:
Node:fas8200-01
DIMM CECC Multiple Err
Name Count Same Address
------- ------ ------------
DIMM-1 0 false
DIMM-2 0 false
DIMM-3 1767 false
DIMM-4 0 false
MEMERR-VERBOSE.XML
日志
Node Fas8200-01
DIMM Name DIMM-3
Correctable ECC Error Count 1767
Multiple Errors on Same Address false