Effective December 3 - NetApp adopts Microsoft’s Business-to-Customer (B2C) identity management to simplify and provide secure access to NetApp resources. For accounts that did not pre-register (prior to Dec 3) access to your NetApp data may take up to 1 hour as your legacy NSS ID is synchronized to the new B2C identity. To learn more, Read the FAQ and Watch the video. Need assistance? Complete this form and select “Registration Issue” as the Feedback Category. 

"sysconfig-a " 将 "failed" 显示为 Flash Cache 状态

Views:
26
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
hw
Last Updated:

适用于

  • FAS3220
  • Data ONTAP 8.

问题

  • ""sysconfig -a 将 "" 显示Failed为 Flash Cache 状态。

示例:

slot 2: Flash Cache 2 (512 GB)
State: Failed 
Model Name: X1973A-R6
Serial Number: 9458198419
Part Number: 111-00902
Board Revision: D0

  • EMS 日志报告“iomem.card.fail.internal:critical”和“fmm.domain.card.failure:error”。

示例:

[?] Sun Feb 23 20:46:52 JST [node_name: iomem.card.fail.internal:critical]: Caching module (model name X1973A-R6, serial number 9458198419, part number 111-00902) in slot 2 has experienced a fatal internal error (0x4007) and is being taken offline.
[?] Sun Feb 23 20:46:52 JST [node_name: fmm_main: fmm.domain.card.failure:error]: Flash Cache in slot 2 (model name X1973A-R6, serial number 9458198419, part number 111-00902): Flash device failed and needs to be updated or repaired or replaced.

 

 