跳转到主内容

"隔离导致冗余不匹配的驱动器"是什么意思?

Views:
35
Visibility:
Public
Votes:
0
Category:
disk-drives
Specialty:
esg
Last Updated:

可不使用  

适用场景

E 系列

问题解答

Isolation of drive causing redundancy mismatch MEL事件类型为2046。

隔离导致冗余不匹配的驱动器是指数据奇偶校验不匹配、因此控制器固件可以将不匹配的情况与单个驱动器隔离。这仅适用于RAID 6卷组和动态磁盘池。

通常、如果已隔离某个驱动器、则可以更换该驱动器、但我们希望先执行故障排除。

有关其他故障诊断步骤、请查看 E系列的驱动器隔离导致冗余不匹配- AutoSupport消息 文章 

追加信息

不适用

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.