从升级或手动重置重新启动后出现SANtricity 控制器数据库错误

Views:
Visibility:
Public
Votes:
0
Category:
e-series-santricity-os-controller-software<a>2009257303</a>
Specialty:
esg
Last Updated:

适用场景

  • SANtricity OS 11.70.x
  • 包含256 TiB或更大卷的磁盘池、以及配置更改历史记录(卷创建、扩展)

问题描述

  • 控制器处于锁定状态、并显示错误代码 OE LtOE LF7段显示屏
  • SANtricity System Manager报告以下内容:
Alternate Controller Database Error
Lockdown code: 0ELt
The storage array has detected an error with the alternate controller's database and has locked down to preserve the data on the storage array. Contact your Technical Support Engineer for assistance correcting this problem.
  • 在串行控制台的每天开始期间、可以看到以下(或类似内容):

(tRAID): ERROR: CrushStripe DeSerialization - Same stripe registered multiple times! Volume 0 SegmentID 0 StripeIndex 100586