跳转到主内容

NetApp_Insight_2020.png 

运行 SANtricity 操作系统 11.60.3 之前版本的 NetApp EF600 报告 " 已超过额定温度 "

Views:
4
Visibility:
Public
Votes:
0
Category:
ef-flash-array
Specialty:
esg
Last Updated:

适用于

运行以下操作系统之一的 NetApp EF600 全闪存阵列:

  • NetApp SANtricity OS 11.60
  • NetApp SANtricity OS 11.60.1
  • NetApp SANtricity 操作系统 11.60.1R1
  • NetApp SANtricity OS 11.60.2

问题

报告以下警报和事件的阵列:

  • AutoSupport 严重警报 Nominal temperature exceeded
  • 的恢复 Guru 警报 NOMINAL_TEMP_EXCEEDED

示例:
Failure Entry 1: NOMINAL_TEMP_EXCEEDED-Recovery Failure Type Code: 7
Storage array: array1
Component reporting problem: Thermal sensor
Status: Nominal temperature exceeded

  • 的严重主要事件日志事件 Event type: 281B 

示例:
Date/Time:  2020-02-20 17:14:38
Sequence number: 2416
Event type: 281B
Event category: Failure
Priority: Critical
Description: Nominal temperature exceeded
Sense Key/ASC/ASCQ: No Additional Sense Information. The controller has no
    sense data available for the requesting host and addressed logical unit
    combination.(0/00/00)
Component type: Temperature Sensor
Component location: Shelf 10
Logged by: Controller in bay A
Tray location (in Hex):a
Slot:1

  • 基板管理控制器( Baseboard Management Controller , BMC )温度警报 Upper Non-critical going high

示例:
 40e | 02/19/2020 | 23:12:05 | System Event #0xff | Timestamp Clock Sync | Asserted
 40f | 02/19/2020 | 23:12:06 | System Event #0xff | Timestamp Clock Sync | Asserted
 410 | 02/20/2020 | 17:11:58 | Temperature #0x1d | Upper Non-critical going high
 411 | 02/20/2020 | 17:12:00 | Temperature #0x1d | Upper Non-critical going high

 