In response to the recent rise in cyber threat due to the Russian-Ukraine crisis, NetApp is actively monitoring the global security intelligence and updating our cybersecurity measures. We follow U.S. Federal Government guidance and remain on high alert. Customers are encouraged to monitor the Cybersecurity and Infrastructure Security (CISA) website for new information as it develops and remain on high alert.

更换控制器后,在 iSCSI 主机接口卡上检测到主机端连接冗余丢失

Views:
3
Visibility:
Public
Votes:
0
Category:
e-series-systems
Specialty:
esg
Last Updated:

适用场景

  • E5700/EF570 和 E2800/EF280 具有 25 GB iSCSI HIC 和 E 系列控制器操作系统 11.60.2 或更高版本
  • 主机接口卡( HIC )
  • AutoCode Sync (自动代码同步)( ACS )
  • 替代控制器具有 11.60.1 或更早版本的固件。

问题描述

  • 更换两个控制器后, AutoSupport 在 iSCSI HIC 上触发以下警报

E-Series Notification (Loss of host-side connection redundancy detected) CRITICAL
E-Series Notification (Host multipath driver configuration error detected) CRITICAL

  • Storage Array Profile 显示了所有八个端口只有两个唯一 MAC 地址的控制器使用的 MAC 地址。

示例如下:

Controller in Shelf 99, Bay A
    Host interface:                     iSCSI
     Host Interface Card(HIC):              1
     Channel:                       5
     Port:                        0e
     Link status:                     Connected
     MAC address:                    be:ef:de:ad:be:ef

在更换控制器之前未观察到此行为:

Controller in Shelf 99, Bay A
    Host interface:                     iSCSI
     Host Interface Card(HIC):              1
     Channel:                       5
     Port:                        0e
     Link status:                     Connected
     MAC address:                    00:a0:98:d5:44:c8

 

Scan to view the article on your device
CUSTOMER EXCLUSIVE CONTENT

Registered NetApp customers get unlimited access to our dynamic Knowledge Base.

New authoritative content is published and updated each day by our team of experts.

Current Customer or Partner?

Sign In for unlimited access

New to NetApp?

Learn more about our award-winning Support