跳转到主内容

E系列控制器冗余丢失—AutoSupport 消息

Views:
4
Visibility:
Public
Votes:
0
Category:
e-series-systems
Specialty:
esg<a>2008978968</a>
Last Updated:

适用场景

NetApp E 系列

事件摘要

SANtricity 报告 Controller redundancy lost Recovery Guru中的事件

验证

  • MAJOR-EVENT-LOG 显示 Controller redundancy lostEvent type: 2829

Date/Time: <DATE/TIME>
Sequence number: 557252
Event type: 2829
Event category: Internal
Priority: Critical
Event needs attention: true
Event send alert: true
Event visibility: true
Description: Controller redundancy lost
Event specific codes: 0/0/0
Component type: Controller
Component location: Shelf 99, Bay B
Logged by: Controller in bay B

  • Recoveru Guru 显示备用控制器 Failed 处于状态:

Failure Entry XX: OFFLINE_CTL-Recovery Failure Type Code: 28

Storage array: <ARRAY>
Component reporting problem: Controller in bay A
Status: Failed
Location: Controller/Drive shelf 99, Controller in bay A
Replacement part number: E5700A-64GB
Board ID: 5700
Submodel ID: 360
Serial number: <SERIAL NO>
Component requiring service: Controller in bay A
Service action (removal) allowed: Yes
Service action LED on component: No

解决方法

  1. 将备用控制器重新联机。
  2. 如果控制器未保持联机状态、请联系 NetApp技术支持 并参考本文以获得进一步帮助。解决方案 可能需要更换部件。
    • 联系 NetApp技术支持时、请在E系列控制器的背面显示上提供7-段代码。这有助于对控制器问题描述 进行故障排除。

追加信息

在此处添加您的文本。

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.