跳转到主内容

ASUP 发送警报电子邮件时未发现任何近期错误

Views:
Visibility:
Public
Votes:
0
Category:
e-series-systems
Specialty:
hw
Last Updated:

适用场景

  • E2824
  • SANtricity OS 11.70R3
  • ASUP ( AutoSupport )

问题描述

ASUP 发送的几封警报邮件,但 GUI 和支持包中的检查无法发现任何近期错误

通知邮件示例 1 :

Dear Support Partner:
 
Below is an AutoSupport note that would normally be sent to a NetApp
Technical Support Engineer or a NetApp Customer as a troubleshooting
Guideline in response to an AutoSupport received by NetApp.
 
NetApp has received an AutoSupport from the following system:
 
SYSTEM DETAILS:
================
SITE NAME:    xxxx
HOSTNAME:   UNNAMED
SERIAL NUMBER:   952000000000
PRIORITY:   P3
 
SYMPTOM:   EPSUFL:E-Series Notification from Unnamed (Power supply failed) CRITICAL
MODEL:   E2824
SW VERSION:   11.70R3 CFW: 08.70.00.03
 
Please review and follow up with your customer.
 
This AutoSupport message indicates there has been problem with your system. Further details can be found in the SANtricity Recovery Guru. A case is being opened to help address the issue

通知邮件示例 2 :

Dear Support Partner:

Below is an AutoSupport note that would normally be sent to a NetApp
Technical Support Engineer or a NetApp Customer as a troubleshooting
Guideline in response to an AutoSupport received by NetApp.
 
NetApp has received an AutoSupport from the following system:
 
SYSTEM DETAILS:
================
SITE NAME:    xxxx
HOSTNAME:   UNNAMED
SERIAL NUMBER:   952000000000
PRIORITY:   P2
 
SYMPTOM:   ESDIAG:E-Series Notification from Unnamed (Controller redundancy lost) CRITICAL
MODEL:   E2824
SW VERSION:   11.70R3 CFW: 08.70.00.03
 
Please review and follow up with your customer.
 
This AutoSupport message indicates there has been problem with your system. Further details can be found in the SANtricity Recovery Guru. A case is being opened to help address the issue.

EMS 日志中检查,这些错误消息是几个月前出现的。

Date/Time: 8/17/21, 6:03:44 AM
Sequence number: 1190
Event type: 283B
Event category: Internal
Priority: Critical
Event needs attention: true
Event send alert: true
Event visibility: true
Description: Power supply failed
Event specific codes: 0/0/0
Component type: Power Supply
Component location: Shelf 1, Power-fan canister 2, Bay 1
Logged by: Controller in bay A

 
Date/Time: 7/19/21, 10:32:15 PM
Sequence number: 211
Event type: 2829
Event category: Internal
Priority: Critical
Event needs attention: true
Event send alert: true
Event visibility: true
Description: Controller redundancy lost
Event specific codes: 0/0/0
Component type: Controller
Component location: Shelf 99, Bay B
Logged by: Controller in bay B

 

Scan to view the article on your device
CUSTOMER EXCLUSIVE CONTENT

Registered NetApp customers get unlimited access to our dynamic Knowledge Base.

New authoritative content is published and updated each day by our team of experts.

Current Customer or Partner?

Sign In for unlimited access

New to NetApp?

Learn more about our award-winning Support