跳转到主内容

VMware 原子测试和设置检测信号会影响与存储的连接

Views:
142
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
virt
Last Updated:

状态信息

适用场景

  • Data ONTAP    
  • SAN协议(iSCSI和FC)
  • VMware vSphere 5.5U2及更长版本
  • 原子测试和设置(Atomic Test & Set、ATS)检测信号

问题描述

  • ESXi主机反复发生LUN重置。  例如、在vmkernel.log中、可以看到类似于以下内容的事件:

2022-04-04T12:33:17.949Z: [scsiCorrelator] 5693120512199us: [vob.scsi.scsipath.por] Power-on Reset occurred on naa.600a0980xxxxxxxxxxxxxxxxxxxxxxx
2022-04-04T12:41:45.715Z: [scsiCorrelator] 5693628237688us: [vob.scsi.scsipath.por] Power-on Reset occurred on naa.600a0980xxxxxxxxxxxxxxxxxxxxxxx
2022-04-04T12:41:48.217Z: [scsiCorrelator] 5693630739987us: [vob.scsi.scsipath.por] Power-on Reset occurred on naa.600a0980xxxxxxxxxxxxxxxxxxxxxxx
2022-04-04T12:41:59.394Z: [scsiCorrelator] 5693641916248us: [vob.scsi.scsipath.por] Power-on Reset occurred on naa.600a0980xxxxxxxxxxxxxxxxxxxxxxx

  • 除了LUN重置之外、还存在数据存储库检测信号超时的证据:

2022-04-04T08:03:16.087Z: [vmfsCorrelator] 5677371531974us: [esx.problem.vmfs.heartbeat.timedout] xxxxxxxx-xxxxxxxx-xxx-xxxxxxxxxxx lun_vmfs_1
2022-04-04T08:03:28.087Z: [vmfsCorrelator] 5677383532045us: [esx.problem.vmfs.heartbeat.timedout] xxxxxxxx-xxxxxxxx-xxx-xxxxxxxxxxx lun_vmfs_2
2022-04-04T08:03:28.087Z: [vmfsCorrelator] 5677383532279us: [esx.problem.vmfs.heartbeat.timedout] xxxxxxxx-xxxxxxxx-xxx-xxxxxxxxxxx lun_vmfs_3
2022-04-04T08:03:28.087Z: [vmfsCorrelator] 5677383532445us: [esx.problem.vmfs.heartbeat.timedout] xxxxxxxx-xxxxxxxx-xxx-xxxxxxxxxxx lun_vmfs_4
2022-04-04T12:33:17.354Z: [vmfsCorrelator] 5693572799758us: [esx.problem.vmfs.heartbeat.timedout] xxxxxxxx-xxxxxxxx-xxx-xxxxxxxxxxx lun_vmfs_5
2022-04-04T12:43:14.401Z: [vmfsCorrelator] 5694169846835us: [esx.problem.vmfs.heartbeat.timedout] xxxxxxxx-xxxxxxxx-xxx-xxxxxxxxxxx lun_vmfs_6

  • 查看主机发出的SCSI命令时、我们发现同时发出ATS (Atomic Test and Set)和SCSI reservation命令:

SCSI预留

2022-04-04T08:03:31.105Z cpu1:2097761)NMP: nmp_PathDetermineFailure:3560: SCSI cmd RESERVE failed on path vmhba64:C2:T1:L3, reservation state on device naa.600a0980383136446f3f4e4c5a484355 is unknown.
2022-04-04T08:03:31.118Z cpu1:2097761)NMP: nmp_PathDetermineFailure:3560: SCSI cmd RESERVE failed on path vmhba64:C2:T1:L3, reservation state on device naa.600a0980383136446f3f4e4c5a484355 is unknown.
2022-04-04T08:03:31.118Z cpu19:2097779)NMP: nmp_PathDetermineFailure:3560: SCSI cmd RESERVE failed on path vmhba64:C2:T1:L2, reservation state on device naa.600a0980383136446f3f4e4c5a484356 is unknown.
2022-04-04T08:03:31.131Z cpu1:2097761)NMP: nmp_PathDetermineFailure:3560: SCSI cmd RESERVE failed on path vmhba64:C2:T1:L3, reservation state on device naa.600a0980383136446f3f4e4c5a484355 is unknown.

ATS比较和写入

2022-04-04T09:35:44.604Z cpu16:2098262)NMP: nmp_ThrottleLogForDevice:3872: Cmd 0x89 (0x45baf02353c0, 2099582) to dev "naa.600a0980xxxxxxxxxxxxxxxxxxxxxxx" on path "vmhba64:C3:T1:L2" Failed: H:0x0 D:0x2 P:0x0 Valid sense data: 0xe 0x1d 0x0. Act:NONE
2022-04-04T12:30:30.386Z cpu27:2098262)NMP: nmp_ThrottleLogForDevice:3872: Cmd 0x89 (0x459adcd68040, 2099582) to dev "naa.600a0980383136446f3f4e4c5a484356" on path "vmhba64:C3:T1:L2" Failed: H:0x0 D:0x2 P:0x0 Valid sense data: 0xe 0x1d 0x0. Act:NONE
2022-04-04T12:33:16.355Z cpu1:2097617)NMP: nmp_ThrottleLogForDevice:3872: Cmd 0x89 (0x45bac31031c0, 2097193) to dev "naa.600a09803831364468244e4c5a47494e" on path "vmhba64:C1:T0:L0" Failed: H:0x5 D:0x0 P:0x0 Invalid sense data: 0x0 0x0 0x0. Act:EVAL
2022-04-04T12:43:13.402Z cpu2:2097617)NMP: nmp_ThrottleLogForDevice:3872: Cmd 0x89 (0x45baf1751140, 2097193) to dev "naa.600a09803831364468244e4c5a47494e" on path "vmhba64:C0:T0:L0" Failed: H:0x5 D:0x0 P:0x0 Invalid sense data: 0x0 0x0 0x0. Act:EVAL

 

 

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.